Percolation Test Results <br /> The completed percolation test form is included in Appendix 3 of this report. The form <br /> was signed by Mr. Tasiopoulos and indicates the percolation rate for the hole based on <br /> the final water drop observed. <br /> Per San Joaquin County Environmental Health Department's definition, a shallow <br /> percolation test hole has a depth between 36 and 42 inches; a satisfactory percolation <br /> rate for a shallow test is less than or equal to 60 minutes per inch (min/in) drop. For the <br /> Site to utilize a standard septic system, one percolation test must demonstrate a <br /> satisfactory percolation rate within the proposed septic system disposal field. <br /> Details and results of the percolation test are summarized in the following table. <br /> Table 2. Percolation Test Summary <br /> Test No., Percolation Percolation Test Duration Comments <br /> Date Tested Test Rate (see notes) <br /> Depth (ft.) (minuteslinch) <br /> P1 Satisfactory <br /> 8/27/15 3.25 <4.2 4 hr. perc. rate <br /> Shallow Test <br /> Note: A satisfactory percolation rate for a"shallow"test is less than or equal to 60 minutes per inch. <br /> Discussion of Percolation Test Results <br /> The soil within the percolation test area has demonstrated a satisfactory percolation rate <br /> for the use of a standard septic system utilizing leach lines and seepage pits in <br /> accordance with the requirements of the San Joaquin County Environmental Health <br /> Department. <br /> Discussion of Septic System Sizing <br /> No construction is planned for the Site. Any future septic system construction should <br /> follow the San Joaquin County On-Site Wastewater Disposal Standards (2003) where <br /> applicable. <br /> LOGE 1515 Page 7 <br />