Laserfiche WebLink
(§ 6.1) Percolation testing was conducted in the location illustrated on the Tentative Map found _ <br /> in Appendix C to encompass most of the northwest quadrant of proposed Parcel 1. This is where �r <br /> any future development has the potential to occur on this Parcel. The test locations maintain G I� <br /> sufficient distance requirements between the on-site domestic well, property lines, etc. The <br /> following information describes the preparation of the percolation test borings and the actual <br /> percolation testing: <br /> (§6.2, 6.3 and 6.5) On November 10, 2010, 1400 hrs, a shallow pert test borings of 42 inches <br /> and a deeper test boring of 105 inches (8.75 ft) were hand-drilled on proposed Parcel 1 in the vJ <br /> northwest quadrant. The sidewalls of the shallow boring were scored with a pry-bar and the loose <br /> material removed. Two inches of fine gravel was placed at the bottom and a three-inch perforated <br /> PVC pipe was inserted into both test borings. Both borings were pre-saturated at 0900 hrs on <br /> November 11, 2010 with 18 inches of clear water. <br /> (§ 6.4) On November 12, 2010, 0800 hrs,percolation testing commenced. There was no standing <br /> water after the 24-hour soak period in the test borings as illustrated in Table 1 below. : <br /> Consequently, EHD Perc Test Procedure 42 was conducted for both test borings. <br /> The last half hour of the test was witnessed by Mike Escotto, R.E.H.S. of the San Joaquin County <br /> Environmental Health Department. The maximum acceptable pert rate is 60 min/in for shallow �/� <br /> pert tests, and 30 min/in for medium and deep depth pert tests. <br /> (§5.4 and 6.8) The following Table illustrates the proposed Parcel number, septic system <br /> structure to be installed based on the depth of the passing pert rate, proposed acreage, post soak <br /> period status and pert test results for the respective pert test. <br /> TABLE 1 <br /> PERCOLATION TEST RESULTS AND RELATED DATA <br />'4 PROPOSED PARCEL PROPOSED PERC TEST DEPTHS POST SOAK PERC TEST <br /> POTENTIALSEP'fIC ACREAGE PERIOD RESULTS <br /> SYSTEM STRUCTURE ATUS <br /> Parcel 1 3.0 Net Acres 42 INCHES No SjHle <br /> 41.7 min/in <br /> Equivalent Feet of Leacbline Water PASSING <br /> based on number of bedrooms. <br /> Sumps Recommended, <br /> ]OS INCHES::] No S 19.2 minlin <br /> Water PASSING <br /> Parcel 2 9.8 f NetAcres NO PERCOLATION TESTS NNIA <br /> REQUIRED UNTIL THERE <br /> DESIGNATED IS A PROPOSAL TO <br /> REMAINDER BUILD ON THIS PARCEL. <br /> l <br /> I <br /> Page -3- <br /> Chesney Consulting <br />