Laserfiche WebLink
4 Annual Domestic Wastewater System—oundwater Monitoring Report,May 2008 <br /> Sutter Home Winery,Lodi,California <br /> Page 3 <br /> Table 2.Laboratory Analytical Methods,Detection Limits,and MCLS <br /> Constituent Analytical Method Detection Limits Primary MCL Secondary MCL <br /> Specific Conductivity 120.1 1.0µmhos/cm 900µmhos/cm 1,600µmhos/cm <br /> H SM4500-H+B Std.units <br /> Nitrate as Nitrogen 300.0 0.25 mg/L* 10 mg/L <br /> Total Dissolved Solids SM2540C 10 mg/L 500 mg/L 1,000 mg/L <br /> Total Kjeldahl Nitrogen 351.3 1.0 mg/L <br /> Sulfate 300.0 1.0 mg/L* 250 mg/L 500 mg/L <br /> Fixed Dissolved Solids SM254OG 10 mg/L <br /> Notes: <br /> umhos/cm=micromhos per centimeter <br /> mg/L=milligrams per liter=parts per million(ppm) <br /> MCL=California Department of Health Services Maximum Contaminant Level <br /> *Reporting limits vary from 0.25 mg/L to 10 mg/L;see attached lab reports for individual reporting limits. <br /> Table 3. Groundwater Laboratory Analytical Results and Field Parameters (May 19,2008) <br /> Field Measurements Quarterly Laboratory Analyses <br /> Well ID Temp EC pH Nitrate-N TDS TKN EC pH Sulfate FDS <br /> MCL 900* 10 500 900* 250* <br /> deg C umhos/cm std units mg/L mg/L rngiL umhos/cm std units mg/L mg/L <br /> DWS-1 17.62 991 7.40 6.35 626 ND 1000 7.5 78.4 473 <br /> DWS-2 I7.68 785 7.42 3.72 521 ND 829 7.5 74.1 401 <br /> DWS-3 I 18.96 12-10 _L7.16 17.4 758 ND 1220 7.2 68.0 522 <br /> i deg C—degrees Centigrade Temp=temperature TDS=total dissolved solids <br /> umhos/cm=micromhos per centimeter EC—specific conductivity TKN=total Kjeldahl nitrogen <br /> mg/L=milligrams per liter—parts per million(ppm) Nitrate-N=Total Nitrate as N FDS=fixed dissolved solids <br /> MCL=California Department of Health Services Maximum Contaminant Level Primary MCL ND=Not detected <br /> *Recommended Secondary MCL with upper levels of 500 mg/L(sulfate),1,600µmhos/cm(EC);and 1,000 mgll.(TDS) <br /> SUMMARY <br /> The MRP requires the three groundwater monitoring wells associated with the domestic wastewater <br /> leachfield to be sampled on an annual basis. The laboratory analytical results of the groundwater samples <br /> collected from monitoring wells DWS-1, DWS-2, and DWS-3 on May 19, 2008, are generally consistent <br /> with the historic laboratory results (attached). Nitrate-N was detected above the DHS Primary MCL of 10 <br /> milligrams per liter(mg/L)in the groundwater sample collected from DWS-3. Laboratory EC values were <br /> above the recommended DHS Secondary MCL of 900 micromhos per centimeter (µmhos/cm) but below <br /> the upper level of 1,600 µmhos/cm in the groundwater samples collected from DWS-1 and DWS-3. Total <br /> dissolved solids were detected at concentrations above the DHS Secondary MCL of 500 mg/L, but below <br /> the upper level of 1,000 mg/L, in all three groundwater samples. Total Kjeldahl nitrogen was not detected <br /> in any of the groundwater samples. The groundwater gradient on May 19, 2008, was generally to the <br /> west, consistent with historic data (see Figure 3). The next annual sampling event is scheduled for May <br /> 2009. <br /> LIMITATIONS AND SIGNATURE <br /> Condor developed the interpretations and conclusions presented herein in accordance with generally <br /> accepted principles and practice. Conclusions presented in this report are professional opinions based on <br /> limited information obtained at the time of our Site visits. Condor has endeavored to determine as much <br /> as practical about the Site using conventional practices given our scope of services. Condor makes no <br /> representation as to the subsurface conditions at locations or times other than those sampled by our <br /> C4) CONDOR <br />