Laserfiche WebLink
The 5 acre parcels as shown on the Tentative Map should provide ad��q te�rea for disposal of <br /> the clear effluent from the on site septic systems. Soil strata to 10' is S1SdCl. The top 18 to 24" is <br /> slightly darker than the tan layer to 10'. If a sigve analysis wP*a��" llcted.the area at 36-38" <br /> would prgbably be a layer of silty clayey sand. The material at this depth,as excavated was non- <br /> plastic as examined in the field. <br /> PERCOLATION TESTING <br /> The percolation testing was conducted by Earnest F. Smith& Associates. The holes were drilled <br /> (shallow)and sleeved with 4" PVC and approximately 2" of 1/4" gravel was placed in the bottom <br /> of the hole. The procedure complies with the req uirementso e nvironmental Health <br /> Department of San Joaquin County. The field percolation test data reports are included. Mr. Ted <br /> Tasiopoulous, E.H.S.,was present for the required readings. <br /> RECORD OF REPAIRS <br /> A review of repairs of records at the EHD office indicate six repairs in the vicinity of the <br /> intersection of Jack Tone Road and E. Jahant Road. The typical repair was add one 40' leach line <br /> and one 25' pit. One of the repairs installed a 60' leach line and one 48" x 25'pit. <br /> CONCLUSION <br /> There were four holes tested. Two on each parcel. All test holes passed the percolation tests. The <br /> inspector witnessed one test hole on each parcel. The vacant parcel requires a 6,000 SF leach <br /> field. The test hole was approximately 165' from the south ROW of E. Jahant Road and in the <br /> approximate center of the vacant parcel. All data,including past performance records, indicates <br /> the soil will support a single family residence when the on-site septic system is constructed in <br /> accordance with the current standards and ordinances of the EHD of San Joaquin County. The <br /> OSI Biotube Effluent Filter(or equal) is recommended to be installed by the contractor in a 1600 <br /> gallon,two compartment tank. No warranty can be expressed/implied by this report. Excessive <br /> use of a garbage disposal can require pumping of the septic tank at earlier stages than normal. The <br /> homeowner has no indicators telling him when it is time to pump,thus the importance of the filter <br /> and the availability of an inspection procedure thru the riser which is installed to grade. A User <br /> Manual (copy inclosed)is fiunished to our client,which may or may not reach the future <br /> homeowner. <br /> APPENDIX: <br /> "N'-Assessor Parcel Map <br /> "B"-USGS Map, Lockeford, Ca. <br /> "C"- Property Detail,Assessor <br /> z/�o <br />