My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0010080
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KASSON
>
25001
>
2600 - Land Use Program
>
PA-1400101
>
SU0010080
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:34:23 AM
Creation date
9/6/2019 10:34:24 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0010080
PE
2626
FACILITY_NAME
PA-1400101
STREET_NUMBER
25001
Direction
S
STREET_NAME
KASSON
STREET_TYPE
RD
City
TRACY
Zip
95376-
APN
23911015 23918005
ENTERED_DATE
5/29/2014 12:00:00 AM
SITE_LOCATION
25001 S KASSON RD
RECEIVED_DATE
5/29/2014 12:00:00 AM
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\K\KASSON\25001\PA-1400101\SU0010080\APPL.PDF \MIGRATIONS\K\KASSON\25001\PA-1400101\SU0010080\CDD OK.PDF \MIGRATIONS\K\KASSON\25001\PA-1400101\SU0010080\EH COND.PDF \MIGRATIONS\K\KASSON\25001\PA-1400101\SU0010080\EH PERM.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(1) Access driveways shall have a width of no less than twenty-five (25) feet for two-way aisles and <br /> sixteen (16) feet for one-way aisles, except that in no case shall driveways designated as fire <br /> department access be less than twenty (20) feet wide. (Development Title Section 9- <br /> 1015.5[h][1]) <br /> (2) The first hundred feet of the driveway from Kasson Road shall be surfaced and permanently <br /> maintained with base material of appropriate depth and asphalt concrete to provide a durable, <br /> dust free surface. (Development Title Section 9-1015.5[e]) <br /> f. LIGHTING: Lighting shall be provided and comply with the following: <br /> (1) If the parking area is to be used at night, parking lot and security lighting shall be installed. <br /> (Development Title Section 9-1015.5[g]) <br /> (2) Any lighting shall be designed to confine direct rays to the premises. No spillover beyond the <br /> property lines shall be permitted except onto public thoroughfares, provided, however, that <br /> such light shall not cause a hazard to motorists. (Development Title Section 9-1015.5[g][4]) <br /> g. SCREENING: Screening shall be provided and comply with the following: <br /> (1) All storage materials and related activities, including storage areas for trash, shall be screened <br /> so as not to be visible from adjacent properties and public rights-of-way. Screening shall be six <br /> (6) to seven (7)feet in height. Outside storage is not permitted in front yards, street side yards, or <br /> in front of main buildings. (Development Title Section 1022.4[d][2]) <br /> h. SIGNS: Sign details shall be consistent with Chapter 9-1710 of the Development Title and be <br /> included on the Site Plan. All portions of any sign shall be set back a minimum of five (5) feet from <br /> any future right-of-way line, including any corner cut-off (snipe). (Development Title Section 9- <br /> 1710.2[g]) <br /> i. BUILDING CODE REQUIREMENTS: The following California Building Code (CBC) and San <br /> Joaquin County Ordinance requirements will be applicable to the proposed project. The following <br /> conditions shall be addressed prior to submittal of a building permit application to the Building <br /> Inspection Division: <br /> (1) A building permit application including plans will be required for any modification to the <br /> existing hanger. Accessible parking and restroom facilities are required as well as an <br /> accessible route of travel connecting all facilities used in conjunction with the sky diving <br /> school. According to state law, plans must be prepared by a registered engineer or licensed <br /> architect and shall be submitted for review and approval. <br /> (2) Based on our records the existing building identified as an existing 940 sq ft office was <br /> installed under permit number BP-0701040 as a mobile home on a foundation system. The <br /> building is a residence and cannot be used as an office. <br /> (3) Obtain a permit for the installation of a commercial modular to be used as the skydiving <br /> school office. <br /> (4) Pursuant to Table 4-3 of the California Plumbing Code, toilet facilities shall be accessible to <br /> employees at all times, should not be more that 500 feet from where employees are regularly <br /> employed. The plans shall indicate the location of the toilet facilities and the travel distance <br /> from work areas. <br /> (5) Parking spaces will be required to accommodate persons with disability in compliance with <br /> Chapter 11 B of the California Building Code. These parking space(s) shall be located as <br />
The URL can be used to link to this page
Your browser does not support the video tag.