Laserfiche WebLink
SITE PLAN CHECK LIST <br /> SITE PLAN CHECK LIST <br /> • Size: The Site Plan must be drawn on minimum 18'x 24"reproducible material. <br /> • North Arrow, pate and Scale: Use an engineer's scale(Le., 1"to 20'or 1"to 40',preferred). The direction of <br /> "north"should be pointing towards the top of the page. <br /> Streets and Easements: Location and names of all streets and easements bordering on the property with <br /> access details. <br /> • Property Lines: All property fines or boundary lines of the parcel with dimensions. <br /> • Vicinity Map: A vicinity map showing the location of the property In relation to surrounding streets. <br /> Existing and Proposed Development: All existing structures(labeled'existing')and any proposed structures <br /> (labeled'proposed')with dimensions,square footage and distances from other structures and property lines. <br /> Any existing structures planned for removal should be shown with dashed lines. The use and number of floors <br /> should be labeled an each structure. <br /> Parking and Driveways: The location,dimensions and surface material of all existing and proposed parking and <br /> driveways. Calculations indicating the number of required spaces must be shown. (Refer to'County Parking <br /> Lot Standards'), <br /> • Water Welts: The location of existing and proposed water wells onsite and any off-site wells within i50'of the <br /> proposed development. Wells must be meet the fallowing setbacks: <br /> 5'from structures; <br /> 50'from septic tanks; <br /> 100'from leach lines; <br /> 150'from sumps or seepage pits;and <br /> 10'from property lines. <br /> If public water will be utilized,a"will-serve'letter must be submitted from the service provider. <br /> • Sewers and Septic Tanks: The location of the sewer outlet,public sewer hook-up.or existing and proposed <br /> sewage disposal systems and any off-site sewage disposal systems within 150'of the property. <br /> Septic tanks must meet the following setbacks: <br /> - 5'from property fines,structures,driveways and swimming pools; <br /> - 50'from water wells. <br /> Leach lines most meet the following setbacks: <br /> 10'from structures,driveways and swimming pools; <br /> 100'from wells,streams and waterways. <br /> T to 76'from property fines depending on zoning or the location of septic systems on adjoining properties <br /> (this requirement also applies to seepage pits). <br /> If public sewage disposal will be utilized,a`will-serve"tetter must be submitted from the service provider. <br /> • Storm Drainage: The location of existing and proposed storm dralnage facilities(check with Engineering staff <br /> regarding design criteria). If subject to flooding, the 100-year flood elevations must be shown. Indicate any <br /> unusual topographic features of the site(e.g. steep slopes,or drainage courses). Grading and contours need to <br /> be shown. <br /> • Landscaping The location of existing and proposed landscaping and trees 6"or greater in diameter(note any <br /> trees to be removed). Calculation indicating the percentage of the net site area to be landscaped must be <br /> shown. (Refer to County Landscaping Standards). <br /> • Signs, Fences,Storage and Trash Enclosures: The location of and height of all existing and proposed signs <br /> and fences and the location and dimensions of all open and/or enclosed storage and trash receptacles. <br /> SITE PLANS MUST BE COMPLETE AND LEGIBLE <br /> • Before applying,check your Site Plan to make sure that it contains all of the information cited above. You are <br /> encouraged to have one of our counter staff review your draft Site Plan prior to Having copies run. <br /> Faint prints and light blue lines will not be accepted because they cannot be reproduced or microfilmed- <br /> F SDEVSV1MFW rxNN Applcalim Forms%Usa Aesmil (Revised 0203-10) Page 8 of 9 <br />