My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0004149
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KOSTER
>
36869
>
2600 - Land Use Program
>
QX-96-0001
>
SU0004149
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/27/2020 1:00:10 PM
Creation date
9/6/2019 10:44:51 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0004149
FACILITY_NAME
QX-96-0001
STREET_NUMBER
36869
Direction
S
STREET_NAME
KOSTER
STREET_TYPE
RD
City
TRACY
ENTERED_DATE
5/12/2004 12:00:00 AM
SITE_LOCATION
36869 S KOSTER RD
RECEIVED_DATE
9/22/1996 12:00:00 AM
QC Status
Approved
Scanner
SJGOV\wng
Supplemental fields
FilePath
\MIGRATIONS\K\KOSTER\36869\QX-96-01_EIR 96-3\SU0004149\PUB REC REL APPL.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
782
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
k'q KLEINFELDER <br /> P <br /> screened interval depth, it is Kleinfelder's opinion that the effects of leakage from the canal <br />� P <br /> would not significantly affect the groundwater level in this well and would likely be negligible if <br /> it did. However, future groundwater soundings and resulting flow and gradients should be <br /> assessed for any suspected anomalies, which may be caused by leakage from the Delta Mendota <br /> Canal. Mr. Borges from the PHS/EHD has additionally requested that the deep wells be <br /> monitored for general minerals on an Annual basis. <br /> In addition to the PHS/EHD request, the San Joaquin County Community Development <br /> Department of Development Services Division (CDD) has requested that three shallow wells be <br /> installed to monitor potential perched water and/or seepage between the Delta Mendota Canal <br /> and a proposed settling basin and in the vicinity of the California Aqueduct near the southwest <br /> corner of the subject site. Quarterly groundwater-level monitoring of these three wells and <br /> annual reporting has been requested. The following scope of service address these items. <br /> PROPOSED SERVICES <br /> Task E01 -Permitting and Pre-Field Activities <br /> Based on the verbal approval of the client, this scope of work(less the cost estimate and contract) <br /> will be submitted to the San Joaquin County Public Health Services Department Environmental <br /> Health Division (PHS/EHD) and CDD for approval. Kleinfelder will obtain boring/monitoring <br /> well permits from the PHS/EHD. The PHS/EHD must approve the proposed scope of work and <br /> ' the boring permits prior to any exploratory borings greater than 18 inches in depth. <br /> Additionally, PHS/EHD will charge DSS an initial 3-hour minimum and any additional oversight <br /> charges above the permit fees to be submitted by Kleinfelder. These fees will be billed directly <br /> to DSS by the PHS/EHD. Kleinfelder will forward the appropriate "billing and compliance <br /> acknowledgement forms" to DSS for signature. Signed originals of the forms and the initial 3- <br /> hour oversight fees must be submitted to PHS/EHD as part of the permit process. <br /> The drilling subcontractor will be responsible to contact Underground Service Alert 48 hours <br /> prior to conducting fieldwork to notify local utilities of our proposed subsurface assessment. <br /> Task E02—Monitoring Well Installation <br /> Three (3) monitoring wells will be installed at the DSS Company Tracy facility located west of <br /> Koster Road, between the California Aqueduct and the Delta Mendota Canal, in Tracy, <br /> California (Plate 1). Two wells will be installed between the Delta Mendota Canal and the <br /> settling basin located near the eastern boundary of the site in the vicinity of a proposed gravel pit. <br /> The third well -Will be installed near the southwestern Rortion of the site just northeast of the <br /> California _Aoue uct. Based upon approximate elevations of the Delta Mendota Canal and <br /> California Aqueduct invert reported by DSS, the three shallow monitoring wells will be installed <br /> to total depths of approximately 35 feet below ground surface (bgs). The purpose of these <br /> 20-YPO-212R/2000P29112000W027 Page 2 of 7 <br /> CD 2000 Kleinfelder,Inc. August 16,2000 <br />
The URL can be used to link to this page
Your browser does not support the video tag.