f5sz°3 La Y x ;: , <br /> I <br />! <br /> SITE PLAN CHECK.LIS T <br /> w <br /> - <br /> • Site: The site plan must be drawn on 18"x 26-reproducible material. - <br /> • North Arrow,Date and Scale: Use an engineer's scale(I.e., l"to 20'or 1"to 40,preferred). The direction of <br /> "north"should be pointing towards the top of the page. <br /> Streets and Easements: Location and names of all streets and easements bordering on the property with access <br /> details. <br /> i <br /> • Property Llnes: All existing and proposed property lines or boundary lines of thearcel with th dimensions. Labe! <br /> each Parcel 1,2,3,4, etc.and indicate the nets square footage(acreage)acrea aJ <br /> q nota a of each <br /> Vicinity Map: A vicinity map showing the location of the property in relation to surrounding streets. <br /> Names and Signatures: Name,signature,address and telephone number of owner,the name,address and , <br /> telephone number of the owner,surveyor or engineer tiling the map. <br /> Confour Lines: Contour lines or spot elevation relative to mean sea level datum. <br /> Dedications; Improvements and easements to be dedicated to the County. <br /> 3 , <br /> - Existing and Proposed Development: All existing structures(labeled'existin ° <br /> gJ and any proposed structures i <br /> (labeled'proposed)with dimensions,square footage and distances from other structures and existing and <br /> proposed property lines. Any existing structures planned for removal should be shown with dashed lines. The <br /> use and number of floors should be labeled on each structure. hou se S r e t.c • r <br /> z <br /> • Parking and Driveways: The location, dimensions and surface material of all existing and proposed parking and <br /> driveways. ttt <br /> 4 <br /> Water Wells: The location of existing and proposed water wells on-site and any off-site wells within 150'Of the <br /> proposed development. Wells must be meet the following setbacks: <br /> 5'from structures; <br /> 50'from septic tanks; <br /> 100'from leach lines; € <br /> 150'from sumps or seepage pits;and <br /> 10'from property lines. 1 <br /> F <br /> If public water will be utilized,a "will-serve"letter must be submitted from the service provider. <br /> i <br /> Sewers and Septic Tanks: The location of the sewer outlet public sewer hook-up, or existing and proposed <br /> sewage disposal systems including leach field areas and any off-site sewage disposal systems within 150'of the <br /> property. s <br /> 3 <br /> i <br /> Septic tanks must meet the following setbacks: <br /> S'from property lines,structures,m driveways and swimming pools; <br /> 50'from water wells. <br /> teach lines must meet the following setbacks: <br /> 10'from structures, driveways and swimming pools; <br /> 100'from wells,streams and waterways. <br /> 5'to 75'from property lines depending on zoning or the location of septic systems on adjoining <br /> properties(this requirement also applies to seepage pits). <br /> If public sewage disposal will be utilized,a "will-serve"letter must be submitted from the service provider. <br /> ! Storm Drainage: The location of existing and proposed storm drainage facilities(check with Engineering staff i <br /> regarding design criteria). If subject to flooding, the 100-year flood elevations must be shown. indicate any I <br /> unusual topographic features of the site(e.g.steep slopes, or drainage courses). <br /> f <br /> I y <br /> Watercourses: The location of existing watercourses and the extent of any levee, with toe and cr:^wn irdreated. <br /> • Flooding: The area subject to flood from an intermediate regional flood and depth of flood wzfers,i;-app!icable. <br /> Proposed method of flood protection If property is subject to inundation from an intermediate reglc:--f•'f',_•od or i <br /> other flood hazard. <br /> 7 I <br /> SITE PLANS MUST BE COMPLETEAND LEGIBLE . .•r <br /> �.�. <br /> ! <br /> Before applying,check your site plan to make sure that it contains all of the information cited above. You are <br /> encouraged to have one of our counter staff review the draft Site Plan prior to having copies run. <br /> • Faint prints and light blue lines cannot be accepted because they cannot be reproduced or microfilmed. <br /> _7- <br /> r <br /> I <br />