Laserfiche WebLink
Watts Winery %W 1 Page 7 of 14 <br /> Our Project Number: LGS090507 <br /> May 11, 2009 <br /> 1.6.5 Percolation Test Procedure <br /> Percolation tests were conducted for the borings on March 24, 2009 in accordance with the <br /> requirements of the EHD. A percolation test with duration of four hours was performed for the <br /> tests. The last half an hour of the test was observed by Michael Escotto, Senior Registered <br /> Environmental Health Specialist, EHD. <br /> Measurement of the water level during the percolation test was from a fixed reference point on <br /> _. the PVC casing using an electric well sounder with a depth accuracy of 1/100th foot. All <br /> tabulated values on the field data sheet (appendix) are in decimal feet. After water drop was <br /> observed, the holes were checked for refill. The refill level was approximately 0.5 ft (6 inches) <br /> of water above the bottom level of the percolation test hole. The readings were taken every 30 <br /> minutes for a period of four (4) hours. <br /> 1.6.6 Percolation Test Forms and Results <br /> The completed percolation test form is included in the appendix of this report. <br /> A shallow percolation test is defined by the EHD as being between 36 and 42 inches in depth; a <br /> satisfactory percolation rate for a shallow test is less than or equal to 60 minutes per inch drop. <br /> A deep percolation test is defined as being between 3.5 and 25 feet in depth; a satisfactory <br /> percolation rate for a deep test is 30 min/in or less. One percolation test must demonstrate a <br /> satisfactory percolation rate within the proposed septic system disposal field of each parcel to <br /> utilize a standard septic system. Details of the percolation tests are summarized in the table <br /> below. <br /> Table 3. <br /> Sum ary of Percolation Tests. <br /> Test No., Percolation Test Percolation Rate Test Duration Comments <br /> _ Date Tested Depth (ft.) (minutes/inch) (see notes) <br /> P-1 (deep) 4.00 50 4-hr Failing perc rate <br /> 03-24-09 <br /> P-2 (shallow) 3.30 50 4-hr Satisfactory perc rate <br /> 03-24-09 <br /> 03 (deep) 4.65 41.67 4-hr Failing perc rate <br /> 03-24-09 <br /> Note: A satisfactory percolation rate for a"shallow"test is less than or equal to 60 minutes per inch. <br /> A satisfactory percolation rate for a"deep"test is less than or equal to 30 minutes per inch. <br /> 1.6.7 Discussion of Percolation Test Results <br /> The soils within the sewage disposal areas of the site have demonstrated a satisfactory <br /> percolation rate in accordance with the requirements of the EHD for the use of a standard <br /> septic system. Percolation test P-1 and P-2 were failing due to the restriction that a "deep" <br /> percolation test must demonstrate less than or equal to 30 minutes per inch percolation. <br /> 902 Industrial Way•Lodi,CA 95240•209.367.3701 •Fax 209.369.4228 02009 Neil O.Anderson&Associates.lac <br />