Laserfiche WebLink
ASSURED INSPECTION MANAGEMENT <br /> OOF AIM <br /> TESTING LABORATORY <br /> (Page 4 ) <br /> VII SOIL PROFILE AND PERCOLATION TESTS (Continued) <br /> Percolation tests were commenced on May 13 , 1991 by a <br /> representative of our firm. Three ( 3 ) percolation tests <br /> conducted at a depth of 42" were disregarded as part of this <br /> report due to failure of water to percolate within the <br /> established requirements set forth by San Joaquin County. <br /> Three ( 3 ) percolation tests performed to the maximum depth <br /> allowed of 25 feet were found to be satisfactory upon completion <br /> of testing. Due to sandy soil conditions and faster percolation <br /> rates, readings were taken 10 minutes apart over a one hour <br /> period. The readings obtained during the last 10 minutes of <br /> testing were used to calculate the percolation rate in minutes <br /> per inch. The results were about one ( 1 ) minute per inch. See <br /> enclosed test data. <br /> VIII CONCLUSION <br /> Based on the past performance of existing septic systems on the <br /> property and nearby properties , the soil profiles encountered, <br /> and the results of the percolation tests; it is our professional <br /> opinion that the subject property is well suited for the <br /> proposed septic system and for the continued use of the present <br /> septic systems . <br /> Sinc ely, oQPprt ,. ;\ <br /> ^ No. <br /> W : <br /> .r . gIFOF CALF <br /> Paul Gillespie <br /> Registered Civil Engineer ==" <br /> 2900 Standiford Avenue, Suite 16B-278 • Modesto, CA 95350 • (209) 523-0754 <br />