My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0000070 SSNL
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
14222
>
2600 - Land Use Program
>
MS-00-07
>
SU0000070 SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/31/2019 5:07:03 PM
Creation date
9/6/2019 11:04:54 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SU0000070
PE
2622
FACILITY_NAME
MS-00-07
STREET_NUMBER
14222
Direction
E
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
ENTERED_DATE
8/8/2001 12:00:00 AM
SITE_LOCATION
14222 E LOUISE AVE
RECEIVED_DATE
5/2/2000 12:00:00 AM
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\sballwahn
Supplemental fields
FilePath
\MIGRATIONS\L\LOUISE\14222\MS-00-07\SU0000070\SS STDY.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PERCOLATION TEST RESULTS: <br /> ON DECEMBER 19, 2000, PARCELS 1 AND THE REMAINDER PARCEL WERE TESTED <br /> TO DETERMINE THE PERCOLATION RATE. MR. LARRY GODINHO, R.D.I. AND <br /> R.E.H.S., FROM THE SAN JOAQUIN COUNTY ENVIRONMENTAL HEALTH <br /> DEPARTMENT OBSERVED THE READINGS FROM 11:00 AM TO 12:30 PM. TWO TEST <br /> HOLES WERE DUG FOR EACH PARCEL. BOTH PERCOLATION TEST HOLES FOR <br /> PARCEL 1 AND THE REMAINDER PARCEL PASSED. PARCELS 1 AND THE <br /> REMAINDER PARCEL PASSED THE PERCOLATION TEST WITH A PERCOLATION <br /> RATE OF 20 MIN/INCH FOR A DEPTH OF 3 FEET. PERCOLATION TESTS WERE <br /> CONDUCTED IN ACCORDANCE WITH SAN JOAQUIN COUNTY ENVIRONMENTAL <br /> HEALTH DEPARTMENT REQUIREMENTS. <br /> COMMENTS REGARDING EXISTING SEPTIC SYSTEMS: <br /> BASED ON THE INFORMATION GIVEN ON SHEET 5, THE EXISTING SEPTIC <br /> SYSTEMS IN THE AREA ARE FUNCTIONING WITH NO PROBLEMS. THE EXISTING <br /> SEPTIC SYSTEMS IN THE AREA CONSIST OF A SEPTIC TANK AND LEACH LINES. <br /> ENGINEER'S OPINION SOIL SUITABILITY: <br /> FROM THE RESULTS OBTAINED FROM THE PERCOLATION TESTS AND EXISTING <br /> PERMITS FOR THE REPAIR AND INSTALLATION OF PRIVATE DISPOSAL SYSTEMS, <br /> THE SEPTIC SYSTEMS FOR PARCELS 1 AND THE REMAINDER PARCEL SHOULD <br /> CONSIST OF A 10, 000 SQUARE FOOT LEACH FIELD AREA. SINCE THE SHALLOW <br /> PERCOLATION TESTS PASSED, SEEPAGE PITS ARE NOT BEING RECOMMENDED TO <br /> BE USED. THE SEPTIC SYSTEM SHOULD CONSIST OF LEACH LINES AND SEPTIC <br /> TANK CONSTRUCTED TO THE SAN JOAQUIN COUNTY ENVIRONMENTAL HEALTH <br /> �► REQUIREMENTS. THE LENGTH OF LEACH LINES AND SIZE OF SEPTIC TANK <br /> SHALL BE DESIGNED FOR THE SOIL CONDITIONS IN THE AREA,AND THE SIZE OF <br /> THE HOUSE OR FACILITY TO BE SERVED. <br /> THE GROUNDWATER TABLE IS LOCATED APPROXIMATELY 39 FEET BELOW THE <br /> GROUND SURFACE. THEREFORE, THE GROUNDWATER LEVEL WILL MEET THE <br /> TEN FOOT MINIMUM DISTANCE BETWEEN THE BOTTOM OF THE LEACH LINES <br /> AND THE TOP OF THE GROUNDWATER TABBLEEER . THE SEPTIC SYSTE SHOULD NO <br /> ITISOURPROFESSIONALecll <br /> �FECT III�INION THAT FINDGOSCLLID,EIN,THIS ST JX <br /> ARE A REPRESENTATIVE ASSESSMENT OF THE PROJECT AREA AT THE PRESENT <br /> TIME. THIS OPINION CANNOT CONSTITUTE A GUARANTEE OR WARRANTY, <br /> EITHER EXPRESSED OR IMPLIED. <br /> WATER TEST RESULTS: <br /> ENCLOSED ON THE FOLLOWING PAGES IS THE TEST RESULTS FOR THE EXISTING <br /> WELL BY FGL ENVIRONMENTAL. MRS. SLIKKER WAS CONTACTED ON JANUARY <br /> .. 12, 2001 IN REGARDS TO WATER FROM THE EXISTING HOUSE EXCEEDING THE <br /> MAXIMUM CONTAMINATION LEVELS FOR NITRATES AND DBCP. A <br /> RECOMMENDATION WAS MADE TO DRINK AND COOK WITH BOTTLED WATER <br /> QROFESSION <br /> q� <br /> ��QO Pp,Y C. <br /> ti:T U JZ <br /> s, -7 n <br /> WONG ENGINEERS, INC. c . c1p, G z'" a <br /> ZACHARY C. WONG, R.C.E. 48717 <br /> J ; <br /> DATED I-17-2001 <br /> OF c- <br /> SHEET 6 q�� 50*0 8'L'11= <br />
The URL can be used to link to this page
Your browser does not support the video tag.