My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WP0039439
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
R
>
ROYAL OAKS
>
1430
>
4200/4300 - Liquid Waste/Water Well Permits
>
WP0039439
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/6/2019 4:33:40 PM
Creation date
9/6/2019 3:20:20 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4200/4300 - Liquid Waste/Water Well Permits
RECORD_ID
WP0039439
PE
4371
STREET_NUMBER
1430
STREET_NAME
ROYAL OAKS
STREET_TYPE
DR
City
STOCKTON
Zip
95209-
APN
07222052
ENTERED_DATE
3/14/2019 12:00:00 AM
SITE_LOCATION
1430 ROYAL OAKS DR
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
TSok
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MOUNTING BRACKET UNl5TRUT FOR MOUNTNG <br /> TYP@ TIFIER(TYP) <br /> AIR-C OLED, RECTIFIER UNIT <br /> (SEE NOTE I &3.) <br /> I-GRS CONDUIT W/(f)-#4 AWG ANODE <br /> AC DISCONNECT SWI CN HEADER CABLE(BLACK), (1)-�4 AWG <br /> STRUCTURE CABLE(WHITE) <br /> 7O AC POWER SUPPLY +— <br /> ANODE JUNCTION BOX <br /> 3• (SEE NOTE 1.} APPROX.0' <br /> I/2"GRS CONDUIT W/AC SEE DL-TAIL 50` <br /> RECTIFIER CABINET POWER TO EX BR]ER PANEL 4 <br /> cPyls PUMP STATION NAME <br /> i4 REBAR 10 INCHES APART, EX PUMP STATION J <br /> EACH WAY& CENTERED IN SLAB 2"GRS CONDUIT W/(2 OR 4 OR 6) — <br /> 2• ft AWG/MALAR HMWPE ANODE CABLES <br /> 6 INCH THICK (BLACK) <br /> CONCRETE PADLa o <br /> CITY OF TOCKTON- <br /> _ I III <br /> LI <br /> 20 IN(TYP) f°GRS CONOw W/(fJ-J4 AWG STRUCTURE RECTIFIER UNIT <br /> CABLE(WH1iF),AND Pl)-#8 AWG TEST <br /> CABLE(WHITE) <br /> 30" <br /> BOLLARD MLN, <br /> SEE DETAfL�j1 <br /> �CPv—�} <br /> 4 FT-8 IN (TYP) TO ANODES <br /> TO PIPELINE <br /> NOTES: <br /> I- ROLIARDS ARE SHOWN IN THE CP STATION SITE PLANS, ARE INDICATED AS NEEDED AT EACH SfTE <br /> 2. BOLLARDS SHALL BE INSTALLED WITH SUFFICIENT SPACE FROM THE CABINETS TO ALLOW FULL NOTES: <br /> OPERATION OF THE CABINET DOORS. V. THE ENGRAVED MICARTA PLATES SHALL BE�s INCH THICK AND <br /> J. CONCRETE MTX SHALL BE TYPE I1 CONCRETE WITH AWATER-TO--CEMENT RATIO BY WEIGHT NOT 70 NOTES: LETTERING SHALL BE� INCH HIGH, WHITE ON BLACK. <br /> EXCEED.55 AND SHALL HAVE A MINIMUM 26--UAY COMPRESSIVE STRENGTH OF 3,000 PST. 1, INSTALL RECTIFIER AND JUNCTION BOX ON THE INTERIOR WALL OF THE PUMP STATION BUILDING. 2 THE PLATES ALLSHAB£HILTED IG THE TE ON <br /> CABINET WITH <br /> 4. CONCRETE REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 60, DEFORMED. 2. FOR CABLE TRENCH, SEE DET&2/CP-20, I/4 INCH DIAMETER BRASS BOLTS. <br /> 5. CONCRETE PAD FINISH SHALL HAVE FINE HAIR LIGHT BROOM FINISH, 3. INSTALL AN AC DISCONNECT SWITCH W/LATCH LOCK ON THE UNISTRUT ABOVE THE JUNCTION BOX. <br /> NEW CONCRETE PAD n WALL-MOUNTED INTERIOR RECTIFIER (�31 RECTIFIER I.D. PLATE <br /> CP-19 NOT TO SCALE GP-I9 NOT TO SCALE GP-19 NOT TO SCALE <br /> NICKEL PLATED ENGRAVED MTCARTA <br /> BRASS HARDWARE sAWX I a s s 5 5 0 o as LABEL (TYP) <br /> COPPER SNORTING ° Oo �° ® #4 AWG/THHN ANODE <br /> STRAP(5k1"91/4 THICK) af a ® ® HEADER CABLE <br /> o o D o o o TO NEW RECDFTER POSITIVE <br /> 0.001 OHM 25 AMP ® ® @ ® ® CABLE PERMANENT NYLON <br /> SHUNT(SEE NOTE 1.) o o 0 o 0 o J'8 AWG THHN TEST CABLE MARKING TAG <br /> COPPER LUG (TYP) <br /> RESISTANCE WIRE <br /> (SEE NOTE 2.) o 0 0 0 <br /> 0 FIBERGLASS JUNCTION BOX AN- I <br /> JS AWG HALAR HMWPE <br /> CABLES FROM ANODES FABRIC REINFORCED <br /> (SEE NOTE 1.) PHENOLIC PANEL <br /> (1/4°THICK) ABBREVIATIONS NUMBER <br /> COVER AN - ANODE ANODE NUMBER <br /> CABLE IDENRFICANON(TYP) DR - DRAIN CABLE <br /> SEE DETAIL X51 1'GRS CONDUIT DPL - DISCHARGE PIPELINE. <br /> �cF-raTT - TEST <br /> 2GRS CONDUIT <br /> NOTES: <br /> f. SEE TABLE I ON SHEET CP-I FOR NUMBER OF ANODES REQUIRED FOR EACH SITE <br /> 2. RESISTANCE WIRE TO BE INSTALLED BY THE ENGINEER. <br /> 3, IDENTIFY CABLES PER DETAIL 5/CP-79. <br /> DEPARTMENT OF MUNICIPAL UTILITIES <br /> 4 ANODE JUNCTION BOX _5_ CABLE IDENTIFICATION CITY OF STOCKTON,CALIFORNIA <br /> CP-19 NOT TO SCALE CF-19 NOT TO SCALE `-- - <br /> � RECOMMENDED: <br /> F.NCINEFRING MANAGER- <br /> NO- P�IS�DNS -RY APP DATE ������u�PROTECTION R�Pf�B�� _ �. ��ar�a�C€MA[N5 DESIGNEDVN7ERTHEDIRECTIONOF: '� -- SKIER 1 <br /> jdh corrosion --- 3-20-2018y ' n <br /> nn ]DEPA t uTCL1T1Ls � <br /> DHPARTIffi\T n ! tan t s, i n ��((�� Ti �� (� f�}I��'1;f[� (f11 G1�1 �1�L �{ I1 I1 Jl A ooa eMnEio ca aas ae°IsrannoN ecwaes s-3a,a aaTe R.cR toss L[ c <br /> ��� .:(Zo k152 _�_� - NJ.� 111111®LVJIV� 11.181 lUJ[I L���ff I`�J�� IJ LS IJ 9�cJ Il]T! ,w,x 1a.pole <br /> 7100 Willow Pass Court, ❑EsiGN:Tpti DATES-aa7 *� <br /> Srockmn,C.i 7.87D Concord, CA 94520 <br /> Pl,onc,(��937-87IXJ DRAWN:TDH DATE:5-3-17 Af F rk <br /> Tel. (925}927-6630 -- - STOCKTON,CALIFORXIA MUNICIPAL UTILITIES DEPARTMENT ° cRt� <br /> lAlIlnOMi YtIInI>;50�AIATIalNf _ __� CHECKL-D.MA DATE:5-3-77 190E 20 SHEEfS ,� <br />
The URL can be used to link to this page
Your browser does not support the video tag.