My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0006490
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
O
>
120 (STATE ROUTE 120)
>
10800
>
2600 - Land Use Program
>
PA-0700108
>
SU0006490
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 4:01:43 PM
Creation date
9/8/2019 12:31:59 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0006490
PE
2622
FACILITY_NAME
PA-0700108
STREET_NUMBER
10800
Direction
E
STREET_NAME
STATE ROUTE 120
City
MANTECA
APN
22803024
ENTERED_DATE
3/27/2007 12:00:00 AM
SITE_LOCATION
10800 E HWY 120
RECEIVED_DATE
3/27/2007 12:00:00 AM
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\O\HWY 120\10800\PA-0700108\SU0006490\APPL.PDF \MIGRATIONS\O\HWY 120\10800\PA-0700108\SU0006490\CDD OK.PDF \MIGRATIONS\O\HWY 120\10800\PA-0700108\SU0006490\EH COND.PDF \MIGRATIONS\O\HWY 120\10800\PA-0700108\SU0006490\EH PERM.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
•.• TEI DATIVE MAP CHECK LIST <br /> TENTATIVE MAP CHECK LIST <br /> • Size: The tentative map must be drawn on 18"x 26"material. <br /> • North Arrow, Date and Scale: Use an engineer's scale(i.e., 1"to 20'or 1"to 40',preferred). The direction of"north"should be <br /> pointing towards the top of the page. <br /> • Streets and Easements: Location and names of all streets and easements bordering on the property with access details. <br /> • Property Lines:All existing and proposed property lines or boundary lines of the parcel with dimensions. Label each Parcel 1,2, <br /> 3,4 or"remainder"and indicate the net acreage of each. A dark,solid line shall be used around the entire original parcel(s). All <br /> proposed parcels and any proposed remainder shall also be lined with a dark solid line. <br /> • Vicinity Map:A vicinity map showing the location of the property in relation to surrounding streets. <br /> • Names: Name,address and telephone number of owner;the name,address and telephone number of the subdivider, surveyor <br /> and engineer filing the map. <br /> • Adjacent Property Owners-Names of adjoining property owners,including those across any easements, roads,waterway, etc. <br /> • Contour Lines: Contour lines or spot elevation relative to mean sea level datum. <br /> • Dedications: Improvements and easements to be dedicated to the County. <br /> • Existing and Proposed Improvements:All existing structures labeled"existing"and any proposed structures labeled"proposed" <br /> with dimensions, square footage and distances from other structures and existing and proposed property lines. Any existing <br /> structures planned for removal should be shown with dashed lines. The use and number of floors should be labeled on each <br /> structure. <br /> • Parking and Driveways:The location, dimensions and surface material of all existing and proposed parking and driveways. <br /> • Water Wells:The location of existing and proposed water wells on-site and any off-site wells within 150'of the proposed <br /> development. Wells must be meet the following setbacks: <br /> 5'from structures; <br /> 50'from septic tanks; <br /> 100'from leach lines; <br /> 150'from sumps or seepage pits;and <br /> 10'from property lines. <br /> If public water will be utilized,a"will-serve"letter must be submitted from the service provider. <br /> • Sewers and Septic Tanks:The location of the sewer outlet, public sewer hook-up,or existing and proposed sewage disposal <br /> systems including leach field areas and any off-site sewage disposal systems within 150'of the property. <br /> Septic tanks must meet the following setbacks: <br /> 5'from property lines, structures, driveways and swimming pools; <br /> 50'from water wells. <br /> Leach lines must meet the following setbacks: <br /> 10'from structures, driveways and swimming pools; <br /> 1 00'from wells,streams and waterways. <br /> 5'to 75'from property lines depending on zoning or the location of septic systems on adjoining properties(this requirement also <br /> applies to seepage pits). <br /> If public sewage disposal will be utilized, a "will-serve"letter must be submitted from the service provider. <br /> • Storm Drainage:The location of existing and proposed storm drainage facilities (check with Engineering staff regarding design <br /> criteria). If subject to flooding,the 100-year flood elevations must be shown. Indicate any unusual topographic features of the <br /> site(e.g.steep slopes,or drainage courses). <br /> • Watercourses: The location of existing watercourses and the extent of any levee,with toe and crown indicated. <br /> • Flooding: The area subject to flood from an intermediate regional flood and depth of flood waters, if applicable. Proposed <br /> method of flood protection if property is subject to inundation from an intermediate regional flood or other flood hazard. <br /> TENTATIVE MAPS MUST BE COMPLETE AND LEGIBLE <br /> • Before applying,check your tentative map to make sure that it contains all of the information cited above. You are encouraged to <br /> have one of out counter staff review your Tentative Map prior to having copies run. <br /> • Faint prints and light blue lines cannot be accepted because they cannot be reproduced or microfilmed. <br /> F:\DEVSVS\Planning Application Forms\Minor Subdivision(Rev.12-09-04) Page 9 of 9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.