Laserfiche WebLink
SA6,10AQUIN p <br /> 2 �Z Environmental Health Department <br /> COUNTY— Linda Turkatte, REHS, Director <br /> c9i,•iP Greatness grows here. Kasey Foley, REHS,Assistant Director <br /> PROGRAM COORDINATORS <br /> Robert McClellan, REHS <br /> Jeff Can uesco,REHS, RDI <br /> Willy Ng, REHS <br /> Muniappa Naidu, REHS <br /> Michael Kith, REHS <br /> April 23, 2019 <br /> To: San Joaquin County Community Develop nt Department <br /> Attention: Alisa Goulart <br /> From: Naseem Ahmed; (209) 468-3436 ��X 1/�M1VA�1 <br /> Registered Environmental Health Specialist <br /> RE: PA-1800300 (UP) Revised , S00012262 1 <br /> 11150 E. Hwy 120, Manteca <br /> The following requirements have been identified as pertinent to this project. Other requirements <br /> may also apply. These requirements cannot be modified. <br /> A. A soil suitability and nitrate loading study incorporating proposed staff and customer use <br /> shall be submitted to the Environmental Health Department, indicating that the area is <br /> suitable for septic system usage. The studies must be approved by the Environmental <br /> Health Department prior to issuance of building permit(s). (San Joaquin County <br /> Development Title, Section 9-1105.2(d)). The fee will be based on the current schedule at <br /> the time of payment. <br /> The sewage disposal system shall comply with the onsite wastewater treatment systems <br /> standards of San Joaquin County prior to approval. A percolation test conducted in <br /> accordance with the E.P.A. Design Manual - Onsite Wastewater and Disposal Systems is <br /> required for each parcel. The fee will be based on the current schedule at the time of <br /> payment. <br /> B. Submit to the Environmental Health Department revised site plans showing the location and <br /> configuration of any existing and proposed sewage disposal systems, along with the area <br /> required to be reserved for future sewage disposal repair/replacement (area for 100°/% <br /> sewage disposal replacement). The plans shall include the design calculations, including <br /> the maximum number of persons the sewage disposal system is proposed to serve. In <br /> addition, show on revised plans that the disposal field area will be barricaded so it cannot <br /> be driven over, parked on, or used as a storage area. This disposal field area must be used <br /> for that specific purpose only, and it cannot contain any underground utility lines (San <br /> Joaquin County Development Title, Section 9-1110.4(c)(5)). <br /> C. The existing private water wells shall be tested for the chemical Dibromochloropropane <br /> (DBCP) and nitrates with the results submitted to the Environmental Health Department <br /> prior to issuance of building permit(s). Samples are to be taken and analyzed by a State- <br /> approved laboratory (San Joaquin County Development Title, Section 9-1115.7). <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />