Laserfiche WebLink
Percolation Test Results <br /> The completed percolation test forms are included in Appendix 3 of this report. The <br /> forms were signed by Mr. Escotto and indicate percolation rates for the holes based on <br /> the final water drop observed. <br /> Per San Joaquin County Environmental HB Department's definition, a shallow <br /> percolation test hole has a depth between'3�ff and '42 inches; a satisfactory percolation <br /> rate for a shallow test is less than or equal 60 ml ' utes per inch (min/in) drop. A deep <br /> percolation test hole has a depth greeter tha 3.5 up to 25 feet; a satisfactory <br /> percolation rate for a deep test is 30 minl'n or ss. For the Site to utilize a standard <br /> septic system, one percolation test (either a shallow or deep test) must demonstrate a <br /> satisfactory percolation rate within the proposed septic system disposal field. <br /> Only shallow tests were performed for the proposed parcels of the Site. Details and <br /> results of the percolation tests are summarized in the following table. <br /> Table 2. Percolation Test Summary <br /> Test No., Percolation Percolation Test Duration Comments <br /> Date Tested Test Rate (see notes) <br /> Depth (ft.) (minutes/inch) <br /> P1, Satisfactory <br /> 12/7/11 3.20 1.8 1 hr. <br /> Shallow Test pert. rate <br /> P2 Satisfactory <br /> 12/7/11 3.30 41.7 1 hr. perc. rate <br /> Shallow Test <br /> Note: A satisfactory percolation rate for a "shallow" test-is less than or equal to 60 minutes per inch. A satisfactory <br /> percolation rate for a "deep"test is less than or equal to 30 minutes per inch. <br /> Discussion of Percolation Test Results <br /> The soils within the percolation test areas have demonstrateda satisfactory percolation <br /> rate for the use of a standard septic system in accordance w re uirements of th <br /> San Joaquin County Environmental Health Department. <br /> Discussion of Septic System Sizing <br /> Septic system construction utilizing leach lines and sumps should follow the San <br /> Joaquin County On-Site Wastewater Disposal Standards (2003) where applicable. — <br /> LOGE 1135 Page 7 <br />