Laserfiche WebLink
Cotta Property, Site 4 Page 9 of 10 <br /> Our Project Number: LGS080515 <br /> May 30, 2008 <br /> ,/ .0 CONCLUSIONS <br /> In summary, percolation rates that meet the minimum EHD standards were achieved in the <br /> proposed septic disposal areas of each of the proposed parcels. Groundwater was encountered <br /> at approximately 5.5 feet on site. The parcels appear suitable for the use of a mounded septic <br /> system or a raised filter bed to maintain the San Joaquin County required minimum distance of <br /> five (5) feet between first groundwater and trench bottom level. <br /> A well water sample was taken from the domestic well on site for Nitrate and DBCP. Neither <br /> nitrate nor DBCP were found in the well water sample. <br /> ,4.0 LIMITATIONS <br /> The conclusions of this report are based on the information provided regarding the existing and <br /> proposed development, the use of the subject property, and the site conditions as they existed <br /> at the time we excavated our test holes and performed the percolation tests. It was assumed <br /> that the test holes and percolation test results are representative of the subsurface conditions in <br /> the general area. <br /> Our professional services were performed, our findings obtained, and our conclusions proposed <br /> in accordance with generally accepted engineering principles and practices. This warranty is in <br /> lieu of all other warranties either expressed or implied. Test findings and statements of <br /> professional opinion do not constitute a guarantee or warranty, expressed or implied. <br /> A <br /> 902 Industrial Way•Lodi,CA 95240• 209.367.3701 •Fax 209.369.4228 02008 Neil O.Anderson&Associates.Inc <br />