My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0002158
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PONDEROSA
>
7960
>
2600 - Land Use Program
>
UP-01-05
>
SU0002158
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:29:03 AM
Creation date
9/8/2019 12:46:22 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0002158
PE
2626
FACILITY_NAME
UP-01-05
STREET_NUMBER
7960
Direction
S
STREET_NAME
PONDEROSA
STREET_TYPE
ST
City
FRENCH CAMP
ENTERED_DATE
10/23/2001 12:00:00 AM
SITE_LOCATION
7960 S PONDEROSA ST
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\P\PONDEROSA\7960\UP-01-05\SU0002158\APPL.PDF \MIGRATIONS\P\PONDEROSA\7960\UP-01-05\SU0002158\CDD OK.PDF \MIGRATIONS\P\PONDEROSA\7960\UP-01-05\SU0002158\EH COND.PDF \MIGRATIONS\P\PONDEROSA\7960\UP-01-05\SU0002158\EH PERM.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
87
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SITE FLAN CHECK LIST <br /> SITE PLAN CHECKLIST <br /> • Size: The Site Plan must be drawn on minimum 18"x 24"reproducible material. <br /> • North Arrow, Date and Scale: Use an engineer's scale(i.e., 1"to 20'or 1"to 40',preferred). The direction of <br /> "north"should be pointing towards the top of the page. <br /> • Streets and Easements: Location and names of all streets and easements bordering on the property with <br /> access details. <br /> • Property Lines: All property lines or boundary lines of the parcel with dimensions. <br /> • Existing and Proposed Development: All existing structures(labeled'existing)and any proposed structures <br /> (labeled'proposed')with dimensions,square footage and distances from other structures and property lines. i <br /> Any existing structures planned for removal should be shown with dashed lines. The use and number of <br /> floors should be labeled on each structure. <br /> • Parking and Driveways: The location,dimensions and surface material of all existing and proposed parking <br /> and driveways. Calculations indicating the number of required spaces must be shown. (Refer to 'County <br /> Parking Lot Standards). <br /> i <br /> • Water Wells: The location of existing and proposed water wells on-site and any off-site wells within 150'of the <br /> proposed development. Wells must be meet the following setbacks: <br /> 5'from structures; <br /> 50'from septic tanks; <br /> 100'from leach lines; <br /> 150'from sumps or seepage pits;and <br /> 10'from property lines. <br /> If public water will be utilized,a "will-serve"letter must be submitted from the service provider. <br /> • Sewers and Septic Tanks: The location of the sewer outlet,public sewer hook-up,or existing and proposed + <br /> sewage disposal systems and any off-site sewage disposal systems within 150'of the property. <br /> Septic tanks must meet the following setbacks: <br /> 5'from properly lines,structures,m driveways and swimming pools; <br /> 50'from water wells. <br /> Leach lines must meet the following setbacks: <br /> 10'from structures,driveways and swimming pools; <br /> 100'from wells,streams and waterways. <br /> 5'to 75'from property lines depending on zoning or the location of septic systems on adjoining <br /> properties(this requirement also applies to seepage pits). <br /> If public sewage disposal will be utilized,a "will-serve"letter must be submitted from the service provider. <br /> • Storm Drainage: The location of existing and proposed storm drainage facilitles(check with Engineering staff <br /> regarding design criteria). 1f subject to flooding,the 100-year flood elevations must be shown. Indicate any <br /> unusual topographic features of the site(e.g.steep slopes,or drainage courses). <br /> • Landscaping: The location of existing and proposed landscaping and trees 6"or greater in diameter(note any <br /> trees to be removed). Calculation indicating the percentage of the net site area to be landscaped must be <br /> shown. (Refer to County Landscaping Standards). <br /> • Signs,Fences, Storage and Trash Enclosures: The location of and height of all existing and proposed signs <br /> and fences and the location and dimensions of all open and/or enclosed storage and trash receptacles. <br /> • Grading and Contours need to be shown. <br /> SITE PLANS MUST BE COMPLETE AND LEGIBLE <br /> Before applying,check your Site Plan to make sure that It contains all of the information cited above. You are <br /> encouraged to have one of our counter staff review your draft Site Plan prior to having copies run. <br /> Faint prints and light blue lines cannot be accepted because they cannot be reproduced or microfilmed. <br /> J <br />
The URL can be used to link to this page
Your browser does not support the video tag.