Laserfiche WebLink
SEPTICSYSTENT CONSTRUCTION <br /> All septic system requirements must be in accordance with the San Joaquin County Environmental Health Se�va(_7e Standards. <br /> For gravity systems, the house Pad HILISt be raised to permit gravity flow through both septic tanks and into leach field. <br /> The double septic system design shown on this plan must comply with the followlria:(Sec. 10 Sewage Standards.) MIN. 25' DEEP <br /> SEEPAGE PITS (TYP.) <br /> NlunInUin distance from well to seepage pits 150' <br /> Minimum distance from trenches to well 100, <br /> Nlinuni-im distance from foundations,driveways and pools 10, <br /> Nlaxiinum length of individual leach line 100, <br /> NlaxiMUM width of trench 24" <br /> Maximum grade of line 3"per 100' <br /> Preferable grade of line 2"per 100' <br /> Distance between lines 10'edge to edge <br /> NlinirnUrn depth of rock below approved perforated pipe 12" <br /> Minimum depth of rock over approved perforated pipe 2" <br /> Maximum depth of trench 42" <br /> Nlinnnum distance between leach line and septic tank 5' <br /> I I LEACHLINES AND TRENCHES <br /> Nfaximurn soil cover over leach line 24" (TYP. -MIN, 10' EDGE TO EDGE) <br /> Minimum soil cover over leach line 6" <br /> During leachfield construction,die sidewalls and floors of the leachline trenches must be scarifie&o open smeared soil surfaces possibly <br /> caused from the backhoe excavations. Seepage pits are normally scarified by a"cleat"on the outsize of the auger flight. All excavations <br /> Should be inspected by a representative from San Joaquin County Public Health Services Department Environmental Health Division, <br /> before placement of drain rock. Telephone at least 48-hours in advance cf inspection (209) 468-3284. <br /> Leachl.-teld areas cannot be driven or parked over,and no structures can be built over these areas. Final grading of the leachfields must <br /> be such that drainage water from domestic irrigation or rainfall cannot collect and pond over tlz, leachfields. Only grasses and small <br /> slinubs may be planted over the fields,with trees and large shrubs planted at least 15 feet away. The designated replacement area Must <br /> remain as such,with no permanent structures built in this area. <br /> SEPTIC SYSTENT iNTAINTENANCE <br /> The septic system installed for the respective residence must consist of a dual leachfield system in accordance with San Joaquin Sewage <br /> Standards,Section 10.1. For the system to have maximum theoretical longevity,the leachfields must be manually switched between <br /> each other on an annual basis.This can be accomplished with a push-pull"gate"valve,which v/ill be on each of the two effluent lines DISTRIBUTION <br /> BOX(TYP.) 0 <br /> DISTRIBUTION <br /> UT <br /> exiting the secondary septic Link. It may be a requirement by the Environmental Health Department that the valves be located within SECONDARY SEPTIC TANK 0 PRIMARY <br /> (TYP.) <br /> the second compartment of the secondary tank. This second compartment must also have an installed filter. BULL RUN VALVE o (SEE ATTACHED NOTES) (OR), 0 TANK <br /> The Environmental Health Department will require that the tanks be pumped every three years. Therefore,access to the tanks by pumper (IN CHRISTIE BOX) <br /> trucks must be maintained.Since the septic systems will be installed in fine-grained clay soils,sodium from a water softener may hasten <br /> 0 <br /> the clogging mechanisms of this soil type,which may lead to septic systern failure. Therefore,water softeners should be avoided or PRIMARY SEPTIC TANK <br /> limited in use. Water from domestic irrigation or rainfall must not be allowed to congregate in the leachfield areas. 0 <br /> By signing below,the homeowner has read and understands the constniction and maintenance p-ocedures,as stated above and agrees <br /> to perform these recommended procedures. This information Must be transferred to a buyer upon sale of the applicable residences. <br /> ,RofESSO <br /> SIGNED PRINTED NAME // <br /> DATE E HOUSE <br /> DOUBLE SYSTEM LEACHFIELD REQUIREMENTS <br /> IN ACCORDANCE WITH SAN JOAQUIN COUNTY SEWAGE STANDARDS Exp. 3-31-03 <br /> Leach I ne_LLnqt�j Size of Prirrla and No. and Dia. Lin_.l OF CA PLAN VIEW <br /> No. of BedrootLis Re Secondary Septic Tanks of Seepage Pits and Len2th ft. <br /> _q�j_ No. and_Len t_jj of Leachlines <br /> 2. :Zccc, o'foo rf r-t t, y- s <br /> 2-42"(160 ft eq <br /> 3 300 ft 1200+ 1 &gals' 1270 ft(16,0'+ 140' =300.) <br /> 4 400 ft 1600+ 1600 gals 3-42"(240 ft. eq,) 3-55,ft(240'+ 165' =405') TYPICAL DOUBLE SEPTIC SYSTEM DESIGN PLATE <br /> 5 500 ft 2000+ 2000 gals 3-42"(240 ft eq,) 3--85,ft(240'+255' =495') HEATHER MOOR ESTATES <br /> 6 600 ft 2000+ 2000 gals 4-42"(320 ft eq.) 4-70 ft(320' +280' =600') k4KLEI N FELDER UNIT No. 2 Ai <br /> (Except for septic tank sizes, all requirements above pertain to a single leachfieicl and therefore must be doubled). DATE PRODUCED:10/16/2l�� 1 FD—ATE-- SAN JOAQUIN COUNTY, CALIFORNIA <br /> REVISED <br /> FILENAME:2011 <br />