Laserfiche WebLink
(3) The noise wall shall be included in the Subdivision Improvement Plans. (Development Title <br /> Section 9-1150.10) <br /> (4) The following note shall be placed on the Final Map: <br /> A. At the time of development of Lots1, 2, 7, and 8, if multi-story houses are proposed, the <br /> applicant shall provide proof that the second-story will meet the interior sound level <br /> requirement of 45 dB prior to submittal of any building permit application. <br /> 2. DEPARTMENT OF PARKS AND RECREATION (Staff Contact: Jeff Smith, 953-8800) <br /> a. PARK FEES: Due to the relative small size of the subdivision, less than fifty(50) parcels, the San <br /> Joaquin County Department of Parks and Recreation will require the collection of in-lieu fees for park <br /> development as a requirement for approval of the Map. (Development Title Section 9-1230.8) <br /> 3. COUNTY COUNSEL <br /> a. HOLD HARMLESS PROVISION: Pursuant to Section 66474.9 of the Government Code, the <br /> subdivider shall defend, indemnify, and hold harmless the local agency or its agents, officers, and <br /> employees from any claim, action, or proceeding against the local agency or its agents, officers, or <br /> employees to attack, set aside, void, or annul an approval of the local agency, advisory agency, <br /> appeal board, or legislative body concerning a subdivision, which action is brought within the time <br /> provided for in Section 66499.37 of the Government Code. <br /> 4. ENVIRONMENTAL HEALTH DEPARTMENT(Staff Contact: Mike Escotto, 468-3443) <br /> a. The Environmental Health Department requires a Soil Suitability/Nitrate Loading Study which <br /> indicates that the area is suitable for septic tank usage. This must be performed prior to recordation <br /> of the Parcel/Final Map(Development Title Section 9-1105.2[d]). A nitrate loading study is required, <br /> and a review fee of$465.00 must be paid at the time of submittal to Environmental Health. <br /> The sewage disposal system shall comply with the on-site sewage standards of San Joaquin County <br /> prior to approval. A percolation test that meets absorption rates of the manual of septic tank practive <br /> or the EPA Design Manual for on-site waste water treatment and disposal systems is required for <br /> each parcel. A permit fee of$93.00 per percolation hole is required. <br /> b. The existing private water wells shall be tested for the chemical Dibromochloropropane(DBCP)and <br /> nitrates prior to recordation of the Parcel/Final Map. Samples are to be taken and analyzed by a <br /> State approved laboratory (Development Title Section 9-1115.7). <br /> c. Connection to an approved public water supply system is required. (Development Title Section 9- <br /> 1120.2) <br /> A letter from the water supplier will be required which states that they have the capacity to serve the <br /> development and that the system meets State standards prior to recording the Final Map. <br /> (Development Title Section 9-1100.3) <br /> d. Construction of individual sewage disposal systems under permit and inspection by Environmental <br /> Health is required at the time of development based on the Soil Suitability/Nitrate Loading Study <br /> findings(Development Title Section 9-1110.4). Estate type zoning (R-R1)shall require a double <br /> leach field system with an alternating distribution box to be installed at the time of construction. <br /> San Joaquin County PA-050040 1\Ghana <br /> Community Development Page 10 <br />