SU0006627
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
3291
>
2600 - Land Use Program
>
PA-0700321
>
SU0006627
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:58:59 PM
Creation date
9/8/2019 12:58:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0006627
PE
2632
FACILITY_NAME
PA-0700321
STREET_NUMBER
3291
Direction
S
STREET_NAME
STATE ROUTE 99
City
STOCKTON
APN
17909012
ENTERED_DATE
7/10/2007 12:00:00 AM
SITE_LOCATION
3291 S HWY 99
RECEIVED_DATE
7/10/2007 12:00:00 AM
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\N\HWY 99\3291\PA-0700321\SU0006627\APPL.PDF \MIGRATIONS\N\HWY 99\3291\PA-0700321\SU0006627\CDD OK.PDF \MIGRATIONS\N\HWY 99\3291\PA-0700321\SU0006627\EH COND.PDF \MIGRATIONS\N\HWY 99\3291\PA-0700321\SU0006627\EH PERM.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
58
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SITt=-PLAN CHECK LIST <br /> SITE PLAN CHECK LIST <br /> 7. North <br /> Site Plan must be drawn on minimum 18"x 24" reproducible material. <br /> w, Date and Scale: Use an engineer's scale (i.e., 1"to 20'or 1" to 40', preferred). The direction of <br /> ould be poinfing towards the top of the page. <br /> d Easements: Location and names of all streets and easements bordering on the property with <br /> access details- <br /> Property Lines: All property lines or boundary lines of the parcel with dimensions. <br /> Vicinity Map: A vicinity map showing the location of the property in relation to surrounding streets. <br /> Existing and Proposed Development: All existing structures (labeled 'existing') and any proposed structures <br /> (labeled 'proposed') with dimensions, square footage and distances from other structures and property lines. <br /> Any existing structures planned for removal should be shown with dashed lines. The use and number of floors <br /> should be labeled on each structure. <br /> Parking and Driveways: The location, dimensions and surface material of all existing and proposed parking and <br /> driveways. Calculations indicating the number of required spaces must be shown. (Refer to 'County Parking <br /> Lot Standards'). <br /> Water Wells: The location of existing and proposed water wells on-site and any off-site wells within 150'of the <br /> proposed development. Wells must be meet the following setbacks: <br /> - 5'from structures; <br /> - 50' from septic tanks; <br /> - 100'from leach lines; <br /> - 150'from sumps or seepage pits; and <br /> - 10' from property lines. <br /> If public water will be utilized, a "will-serve" letter must be submitted from the service provider. <br /> Sewers and Septic Tanks: The location of the sewer outlet, public sewer hook-up, or existing and proposed <br /> sewage disposal systems and any off-site sewage disposal systems within 150'of the property. <br /> Septic tanks must meet the following setbacks: <br /> - 5'from property lines, structures, driveways and swimming pools; <br /> - 50' from water wells. <br /> Leach lines must meet the following setbacks: <br /> - 10' from structures, driveways and swimming pools; <br /> - 100'from wells, streams and waterways. <br /> S'to 75' from property lines depending on zoning or the location of septic systems on adjoining properties <br /> (this requirement also applies to seepage pits). <br /> If public sewage disposal will be utilized, a "will-serve" letter must be submitted from the service provider. <br /> Storm Drainage: The location of existing and proposed storm drainage facilities (check with Engineering staff <br /> regarding design criteria). If subject to flooding, the 100-year flood elevations must be shown. Indicate any <br /> unusual topographic features of the site (e.g. steep slopes, or drainage courses). Grading and contours need to <br /> be shown. <br /> Landscaping: The location of existing and proposed landscaping and trees 6" or greater in diameter (note any <br /> trees to be removed). Calculation indicating the percentage of the net site area to be landscaped must be <br /> shown- (Refer to County Landscaping Standards). <br /> Signs, Fences, Storage and Trash Enclosures: The location of and height of all existing and proposed signs <br /> and fences and the location and dimensions of all open and/or enclosed storage and trash receptacles. <br /> SITE PLANS MUST BE COMPLETE AND LEGIBLE <br /> Before applying, check your Site Plan to make sure that it contains all of the information cited above. You are <br /> encouraged to have one of our counter staff review your draft Site Plan prior to having copies run. <br /> Faint prints and light blue lines will not be accepted because they cannot be reproduced or microfilmed. <br /> F•AEVSVCWIann,ng A,l rorms�Slie Approval (Revised t-ova) Page 8 of 9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.