Laserfiche WebLink
SITE PLAN CHECK LIST <br /> SITE PLAN CHECK LIST <br /> • She: The Site Plan must be drawn on minimum 18"x 24"material. <br /> • North Arrow, Date and Scale: Use an engineer's scale(i.e., 1"to 201or 1"to 40',preferred). The direction of"north" <br /> should be pointing towards the top of the page. <br /> • Streets and Easements: Location and names of all streets and easements bordering on the property with access <br /> details. <br /> • Property Lines: All property lines or boundary lines of the parcel with dimensions. <br /> • Vicinity Map: A vicinity map showing the location of the property in relation to surrounding streets. <br /> • Existing and Proposed Development: All existing structures(labeled'existing)and any proposed structures(labeled <br /> proposed')with dimensions, square footage and distances from other structures and property lines. Any existing <br /> structures planned for removal should be shown with dashed lines. The use and number of floors should be labeled on <br /> each structure. . <br /> • Packing and Driveways: The location,dimensions and surface material of all existing and proposed parking and <br /> driveways. Calculations indicating the number of required spaces must be shown. (Refer to'County Parking Lot <br /> Standards). <br /> • Water Wells: The location of existing and proposed water wells on-site and any off-site wells within 150'of the <br /> proposed development. Wells must be meet the following setbacks: <br /> 5'from structures; <br /> 50'from septic tanks; <br /> 100'from leach lines; <br /> 150'from sumps or seepage pits;and <br /> 10'from property lines. <br /> If public water will be utilized,a "will-serve"letter must be submitted from the service provider. <br /> Sewers and Septic Tanks: The location of the sewer outlet,public sewer hook-up, or existing and proposed sewage <br /> disposal systems and any off-site sewage disposal systems within 150'of the property. <br /> Septic tanks must meet the following setbacks: <br /> - 5'from property lines, structures, driveways and swimming pools; <br /> - 50'from water wells. <br /> Leach lines must meet the following setbacks: <br /> - 10'from structures, driveways and swimming pools; <br /> 100'from wells, streams and waterways. <br /> 5'to 75'from property lines depending on zoning or the location of septic systems on adjoining properties(this <br /> requirement also applies to seepage pits). <br /> If public sewage disposal will be utilized, a "will-serve"letter must be submitted from the service provider. <br /> Storm Drainage: The location of existing and proposed storm drainage facilities(check with Engineering staff regarding <br /> design criteria). If subject to flooding, the 100-year flood elevations must be shown. Indicate any unusual topographic <br /> features of the site(e.g. steep slopes, or drainage courses). <br /> Landscaping., The location of existing and proposed landscaping and trees 6"or greater in diameter(note any trees to <br /> be removed). Calculation indicating the percentage of the net site area to be landscaped must be shown. (Refer to <br /> County Landscaping Standards). <br /> Signs, Fences, Storage and Trash Enclosures: The location of and height of all existing and proposed signs and fences <br /> and the location and dimensions of all open and/or enclosed storage and trash receptacles. <br /> SITE PLANS MUST BE COMPLETE AND LEGIBLE <br /> Before applying, check your Site Plan to make sure that it contains all of the information cited above. You are <br /> encouraged to have one of our counter staff review your draft Site Plan prior to having copies run. <br /> Faint prints and light blue lines cannot be accepted because they cannot be reproduced or microfilmed. <br />