My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0004614 ENG DES PLN
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
NAVARRO
>
22350
>
2600 - Land Use Program
>
PA-0400463
>
SU0004614 ENG DES PLN
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:30:58 AM
Creation date
9/8/2019 1:01:34 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
ENG DES PLN
RECORD_ID
SU0004614
PE
2622
FACILITY_NAME
PA-0400463
STREET_NUMBER
22350
Direction
E
STREET_NAME
NAVARRO
STREET_TYPE
CT
City
LINDEN
APN
09303059
ENTERED_DATE
8/23/2004 12:00:00 AM
SITE_LOCATION
22350 E NAVARRO CT
RECEIVED_DATE
8/20/2004 12:00:00 AM
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\N\NAVARRO\22350\PA-0400463\SU0004614\SS STDY_ENG DES.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
58
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
L <br /> June 15,2005 <br /> NOA Project Number: E05065A <br /> LTable 3. <br /> Summary of Percolation Tests. <br /> Test No., Percolation Percolation Rate Test Comment <br /> Date Tested Test Depth(ft) (minutes/inch) Duration (see notes) <br /> P-2 deep,6/3/05 22.96 _ _ 4-hr No water drop observed the <br /> (Parcel 2) last half an hour,fail <br /> P-3 shallow,6/3/05 3.45 __ 4-hr No water drop observed the <br /> (Parcel 3) last half an hour,fail <br /> P-3 deep,6/3/05 5.41 --- 4-hr No water drop observed the <br /> (Parcel 3 last half an hour,fail <br /> Note: A satisfactory percolation rate for a"shallow'test is less than or equal to 60 minutes per inch <br /> A satisfactory percolation rate for a"deep"test is less than or equal to 30 minutes per inch. <br /> The soils within the sewage disposal areas of the septic area have not demonstrated a satisfactory <br /> percolation rate in accordance with the requirements of the EHD. <br /> bw <br /> 1 We recommend a Civil Engineer prepare a septic system design for Parcels 2 and 3 unless additional <br /> percolation testing,performed under EHD oversight, achieves a satisfactory rate. <br /> L Our professional services were performed,our findings obtained, and our conclusions proposed in <br /> accordance with generally accepted engineering principles and practices. This warranty is in lieu of <br /> all other warranties either expressed or implied. Test findings and statements of professional <br /> opinion do not constitute a guarantee or warranty, expressed or implied. <br /> LBest Regards, <br /> LNEIL O.ANDERSON e7ASSOC7ATES, INC. <br /> � CEO13 10 <br /> ` . <br /> Q No. 2151 y <br /> Rebecca Haskett,B.S. J. Welch,M.Sc. CERTIFIED <br /> L Project Manager CEG-2151, CHG-653, GP-1049 ENGINEERING 'J <br /> Environmental Division Manager N], GEOLOGIST Nei <br /> ` ��OF CqL\FO� <br /> LArt: Site Map <br /> Vicinity Map <br /> LPercolation Forms <br /> L <br /> L "004 <br /> L <br />
The URL can be used to link to this page
Your browser does not support the video tag.