Laserfiche WebLink
C) <br /> . �:are€s'av�3:13da:?°°.< -; I� a,Lze• - `€tr, `:^�;'� s;�3s�6e�i !°" �vC.�;».' q:i�: <br /> SANITARY SEWER SEPTIC DESIGN <br /> Project: Munoz, Ag Store Project, 25192 River Road, Escalon, CA <br /> Building Size: 1,125 SF (Ag Store) <br /> No. of Employees: 2 Per Day Total <br /> No. of Bathrooms: 1 Uni-Sex (Employee Public) <br /> Fixture Count: <br /> Kind of Fixture <br /> Water Closets (Toilet) 1 <br /> Wash Basins (Sink) 1 <br /> Total Fixtures = 2 <br /> Per Table 6.1.15 Water Use Computation Factor Table For "Z. Stores per toilet fixture" <br /> 150 Gal/Fixture <br /> - <br /> II'I ADF - 2x150 = 300 Gal. <br /> BTC = 1200 Gal. <br /> Min. Tank Size = STC + ADF = 1200 + 300 = 1500 Gal. <br /> Use 1500 Gallon Tank <br /> �9 Okofo SS Ip <br /> t <br /> Leach Field <br /> Percolation Testing Prepared by N.A.T.S. <br /> Type of Soil: Sandy Silt <br /> * ° o <br /> Percolation Rate = 9.26 Min./In. n N0. C", <br /> Soil Factor = 0.225 9"e EXP. 12-31-10,. <br /> Leach Line = 1500 x 0.225 = 337.5 Ft. <br /> CA41� <br /> Oti <br /> Filter Bed Area Factor = 3 <br /> Filter Bed Area = Leach bine x Factor = 1012.5 SF <br /> Use 32 Ft. x 32 Ft. 11,024 S .Ft. Septic Leach Filter Bed Area <br /> f <br /> 6/30/2009 Page 1 of 1 Job No. 09-113 <br />