Laserfiche WebLink
J <br /> i <br /> i <br /> ff �IWM = <br /> i <br /> SANITARY SEWER SEPTIC DESIGN <br /> Project: Munoz, Ag Store Project, 25192 River Road, Escalon, CA <br /> Building Size: 1,125 SF (Ag Store) <br /> No. of Employees: 2 Per Day Total <br /> No. of Bathrooms: 1 Uni-Sex (Employee/Public) <br /> JUL 0 1 zoos <br /> Fixture Count: ENVIRONMENT HEALTH <br /> Kind of Fixture PERM <br /> Water Closets (Toilet) 1 <br /> Wash Basins (Sink) 1 <br /> Total Fixtures = 2 <br /> Per Table 6.1.15 Water Use Computation Factor Table For "Z. Stores per toilet fixture" <br /> 150 Gal/Fixture <br /> ADF = 2 x 150 = 300 Gal. <br /> BTC = 1200 Gal. <br /> Min. Tank Size = BTC + ADF = 1200 + 300 = 1500 Gal. <br /> Use I5OO Gallon Tank <br /> QtyDEESS# <br /> Leach <br /> ield <br /> Percolation ion Testing Prepared by N.A.T.S. ��!pM D. <br /> Type of Soil:; Sandy Silt 5" <br /> ° <br /> Percolation Rate = 9.26 Min./Tn. * e o <br /> ND. C55910 ° <br /> Soil Factor =. 0.225 EXP, 12-31_14,0 <br /> Leach Line = 1500 x 0.225 = 337.5 Ft. cwI. <br /> E CR CAL 1F <br /> B <br /> Filter Bed Area Factor = 3 <br /> Filter Bed Area = Leach Line x Factor = 1012.5 SF <br /> I <br /> I <br /> Use 32 Ft. x 32 Ft. (1,024 S .Ft. Se tic Leach Filter Bed Area <br /> 4 ' <br />{ t <br /> 6/29/2009 Page 1 of 1 Job No. 09-113 <br />