Laserfiche WebLink
Californi; ,,regional Water Quality Co:.-ol Board <br /> \- Central Valley Region <br /> v goKarl E. Longley,ScD,P.E.,Chair <br /> Linda Adams Sacramento Main Office __ Arnold <br /> Secretaryfor 11020 Sun Center Drive 4200,Rancho Cordova,Cahfom (4f,j� �'J L�t✓ Schwarzenegger <br /> Environmental Phone(916)464-3291 •FAX(916)464-46 Governor <br /> Protection http://www.waterbouds.ca.gov/centralvalley <br /> NiAR 0 i 2007 <br /> 6 March 2007t,-i4j- HEALTH <br /> EiVPVCRM T/ <br /> SERVICES <br /> Jeff Welch <br /> Munn and Perkins <br /> P.O. Box 4760 <br /> Modesto, CA 95352 <br /> INCOMPLETE RWD INFORMATION ADDITIONAL INFORMATION, MUNN AND PERKINS <br /> AGGREGATE FACILITY, E§C L , SAN JOAQUIN COUNTY <br /> Staff has reviewed the 12 February 2007 RCRWQCB Report of Waste Discharge Letter Dated <br /> 5 December 2006 correspondence prepared by Munn & Perkins that requests additional <br /> information on preparation of a Report of Waste Discharge (RWD). You request a list of <br /> analytes, analytical test methods, and detection limits. <br /> Staff has prepared the following table that lists the analytes of concern. The table also <br /> summarizes some of the data submitted in the 10 February 2006 RWD and the appropriate <br /> Water Quality Limit (WQL). For each analyte presented, you can see that the reported <br /> concentration, or the detection limit, is greater than the WQL. <br /> For the instances when the concentration exceeded the WQL, it is possible that the <br /> concentration is due to failure to filter the sample prior to digestion and analysis; the RWD did <br /> not state whether filtering had occurred. Please resample the wastewater, ensure that the <br /> sample is filtered prior to digestion and analysis, and use an analytical method that provides a <br /> sufficiently low detection limit to allow meaningful comparison of the result to the WQL. <br /> For the instances when the detection limit is too high, please perform the sample collection <br /> and preparation as described above but instruct the analytical laboratory of the necessary <br /> detection limit. <br /> Water Quality Data <br /> Analyte Matrix Units Concentration WQL Comment <br /> Arsenic liquid mg/L 0.0084 0.000004 Exceeded WQL <br /> Lead liquid mg/L 0.0055 0.00025 Exceeded WQL <br /> Vanadium liquid mg/L 0.083 0.05 Exceeded WQL <br /> Iron liquid mg/L 23 0.3 Exceeded WQL <br /> Manganese liquid mg/L 1.04 0.05 Exceeded WQL <br /> Nitrogen (Total) liquid mg/L 11 10 Exceeded WQL <br /> Sodium liquid mg/L 29 20 Exceeded WQL <br /> Aluminum liquid mg/L 22 0.05 Exceeded WQL <br /> Cadmium liquid mg/L ND (0"001) 0.00007 Detection limit too high <br /> Thallium liquid mg/L ND (0.10) 0.0001 Detection limit too high <br /> California Environmental Protection Agency <br /> 0 Recycled Paper <br />