My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0004824 SSNL
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
R
>
ROBERTS
>
6891
>
2600 - Land Use Program
>
PA-0500045
>
SU0004824 SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:31:15 AM
Creation date
9/9/2019 9:08:24 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SU0004824
PE
2690
FACILITY_NAME
PA-0500045
STREET_NUMBER
6891
Direction
S
STREET_NAME
ROBERTS
STREET_TYPE
RD
City
TRACY
APN
16211001 TO 04
ENTERED_DATE
2/9/2005 12:00:00 AM
SITE_LOCATION
6891 S ROBERTS RD
RECEIVED_DATE
2/8/2005 12:00:00 AM
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\R\ROBERTS\6891\PA-0500045\SU0004824\SS STDY.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> L N%./ <br /> 60 May 5,2005 <br /> NOA Project Number: E05057A <br /> 6.5 Percolation Test Procedure <br /> Percolation tests were conducted on April 26, 2005 in accordance with the requirements of the <br /> EHD.A percolation test with a duration of four hours was performed for the hole. The final <br /> half-hour of the four-hour percolation tests were observed by Mr. Larry Godinho, Senior Registered <br /> Environmental Health Specialist, EHD. <br /> Measurement of the water level during the percolation test was from a fixed reference point on the <br /> PVC casing using an electric well sounder with an depth accuracy of 1/100th foot. All tabulated <br /> values on the field data sheet (appendix) are in decimal feet.After water drop was observed, the <br /> hi" holes were checked for refill. The refill level was approximately 0.5 ft (6 inches) of water above the <br /> bottom level of the percolation test hole. The readings were taken approximately every 30 minutes <br /> for a period of four hours. <br /> 6.6 Percolation Test Forms and Results <br /> The completed percolation test forms are included in the appendix of this report. <br /> A shallow percolation test is defined by the EHD as being between 36 and 42 inches in depth;a <br /> 60 satisfactory percolation rate for a shallow test is less than or equal to 60 minutes per inch drop. One <br /> percolation test must demonstrate a satisfactory percolation rate within the proposed septic system <br /> disposal field of each parcel to utilize a standard septic system. Details of the percolation tests are <br /> summarized in Table 9. <br /> Table 9. <br /> Summary of Percolation Tests. <br /> Test No., Percolation Percolation Rate Test Comment <br /> Date Tested Test Depth(ft) (minutes/inch) Duration <br /> P-1 shallow,4/26/05 3.45 16.7 4-hr Satisfactory percolation rate <br /> P-2 shallow,4/26/05 3.33 8.93 4-hr Satisfactory percolation rate <br /> P-3 shallow,4/26/05 3.49 --- 4-hr No wat d;op observed,fail <br /> P-4 shallow,4/26/05 3.47 125 4-hr Slow ercolatt n , <br /> ba Note: A satisfactory percolation rate for a"shallow"test is less than or equal to 60 minutes per inch. <br /> bw <br /> 1.. <br /> 10 <br /> .,444 <br /> V <br />
The URL can be used to link to this page
Your browser does not support the video tag.