Laserfiche WebLink
Project Name: Rond Road Property Page 2 of 3 <br /> Our Project Number: LGS080510 <br /> Date: June 4, 2008 <br /> Discussion of Percolation Test Results <br /> Ground water was encountered at six (6) feet on site on April 28, 2008. The soils within the <br /> sewage disposal areas of the site have demonstrated a satisfactory percolation rate in accordance <br /> with the requirements of the EHD for the use of a mounded septic system or raised filter bed. <br /> Discussion of Septic System Sizing <br /> Ground water was encountered at six (6) feet on site on April 28, 2008. Septic system <br /> construction should follow the San Joaquin County On-Site Wastewater Disposal Standards where <br /> applicable utilizing a mounded septic system or a raised filter bed in order to maintain the EHD <br /> minimum required distance of five (5) feet from ground water and trench bottom depth. <br /> CONCLUSIONS <br /> In summary, percolation rates that meet the minimum EHD standards were achieved in the <br /> proposed septic disposal areas of each of the proposed parcels. Ground water was encountered at <br /> six (6) feet on site on April 28, 2008. The parcels appear suitable for the use of a mounded septic <br /> system or a raised filter bed in order to maintain the EHD required minimum distance of five (5) <br /> feet between ground water and trench bottom. <br /> ,.,44 <br /> 902 Industrial Way•Lodi,CA 95240.209.367.3701 •Fax 209.369.4228 02007 Nei!O.Anderson&Associates,Inc. <br />