Laserfiche WebLink
an estimate. The estimate and legal descriptions shall be prepared by a Registered Civil <br /> Engineer with a typical section drawing on a form to be supplied by the Department of <br /> Public Works and submitted to Public Works for approval. As an option, Public Works will <br /> prepare the drawing with estimate for an additional fee of $115.00. (Development Title <br /> Section 9-1100.3) <br /> e. All easements of record shall be shown on the Parcel Map. (Development Title Section <br /> 9-910.20) <br /> f. Any driveway that exceeds 150 feet in length from any public roadway shall be improved <br /> in accordance with the requirements of the Uniform Fire Code Section 10.207, San <br /> Joaquin County Standards F-1 a, F-1 b, and F-1 c, and the Liberty Fire District prior to <br /> issuance of the building permit. (Development Title Section 9-1145.5) <br /> g. Requirements for construction of improvements shall be noticed by a statement on the <br /> Parcel Map. (Subdivision Map Act Section 66411.1) <br /> 3. PUBLIC HEALTH SERVICES: <br /> a. A soil suitability study as required by Section 9-1105.2(d) of the San Joaquin County <br /> Development Code must be performed prior to approval of the parcel map to indicate that <br /> the area is suitable for septic tank usage. (Development Title Section 9-1105.2(d)) <br /> b. The existing private water wells shall be tested for the chemical Dibromochloropropane <br /> (DBCP) and nitrates prior to approval of the parcel map. Samples are to be taken and <br /> run by a State approved lab. (Development Title Section 9-1115.7) <br /> C. Construct an individual sewage disposal system on Parcel 1 under a permit and <br /> inspection by the Environmental Health Division at the time of development. (Ordinance <br /> Code Section 5-3003) <br /> d. Construct an individual domestic water well on Parcel 1 under a well permit and <br /> inspection by the Environmental Health Division at the time of development. (San Joaquin <br /> County Ordinance No. 1862, Section 5-4100) <br /> 4. LIBERTY FIRE DISTRICT: <br /> a. The right-of-way shall have a minimum unobstructed width of not less than 20 feet, and <br /> turnarounds shall be provided for all access roads in excess of 150 feet in length and be <br /> adequate to handle fire apparatus. Vertical road clearance must be unobstructed and <br /> not less than 13 feet, six inches, in height. The surface shall be designed and maintained <br /> to support the imposed loads of fire apparatus for all weather driving capabilities. <br /> (Uniform Fire Code, 1985 edition, Section 10.207) <br /> Conditions of Approval - 2 - MS-92-189 <br />