My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0011890
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
S
>
SPERRY
>
431
>
2600 - Land Use Program
>
PA-1800161
>
SU0011890
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/16/2020 8:45:50 AM
Creation date
9/9/2019 10:18:59 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0011890
PE
2633
FACILITY_NAME
PA-1800161
STREET_NUMBER
431
Direction
E
STREET_NAME
SPERRY
STREET_TYPE
RD
City
STOCKTON
Zip
95206-
APN
17728036
ENTERED_DATE
8/15/2018 12:00:00 AM
SITE_LOCATION
431 E SPERRY RD
RECEIVED_DATE
8/13/2018 12:00:00 AM
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
TSok
Supplemental fields
FilePath
\MIGRATIONS\S\SPERRY\431\PA-1800161\SU0011890\APPL.PDF \MIGRATIONS\S\SPERRY\431\PA-1800161\SU0011890\CDD OK.PDF \MIGRATIONS\S\SPERRY\431\PA-1800161\SU0011890\EH COND.PDF \MIGRATIONS\S\SPERRY\431\PA-1800161\SU0011890\CORRES.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
76
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
( 1 ) Access driveways shall have a width of no less than twenty-five ( 25 ) feet for two -way aisles and <br /> sixteen ( 16 ) feet for one -way aisles , except that in no case shall driveways designated as fire <br /> department access be less than twenty ( 20 ) feet wide . ( Development Title Section 9 - 1015 . 5 [ h ] [ 1 ] ) <br /> ( 2 ) The first 100 feet of the driveway from Sperry Road shall be surfaced and permanently maintained <br /> with asphalt concrete or Portland cement concrete to provide a durable , dust free surface . <br /> ( Development Title Section 9 - 1015 . 9 ) <br /> f . LIGHTING : Lighting shall be provided and comply with the following : <br /> ( 1 ) If the parking area is to be used at night , parking lot and security lighting shall be installed . <br /> ( Development Title Section 9 - 1015 . 5 [g ] ) <br /> The existing lighting meets this requirement . <br /> ( 2 ) Any lighting shall be designed to confine direct rays to the premises . No spillover beyond the <br /> property lines shall be permitted except onto public thoroughfares , provided , however , that such <br /> light shall not cause a hazard to motorists . ( Development Title Section 9 - 1015 . 5 [ g ] [4 ] ) <br /> g . LANDSCAPING : Landscaping shall be provided and comply with the following : <br /> ( 1 ) The existing hardscape design shall be incorporated into the site plan review . This satisfies the <br /> landscaping requirement . ( Development Title Section 9 - 1020 . 7 ) <br /> h . SCREENING : Screening shall be provided and comply with the following : <br /> ( 1 ) All storage materials and related activities , including storage areas for trash , shall be enclosed by <br /> a screen six ( 6 ) to eight ( 8 ) feet in height . Items stored within one hundred ( 100 ) feet of a dedicated <br /> street or residential zone shall not be stacked higher than two ( 2 ) feet above the adjacent screen . <br /> ( Development Title Section 9 - 1022 . 4 [ e] [2 ] [A] ) <br /> i . SIGNS : Sign details shall be consistent with Chapter 9 - 1710 of the Development Title and be included <br /> on the Site Plan . All portions of any sign shall be set back a minimum of five ( 5 ) feet from any future <br /> right- of-way line , including any corner cut- off ( snipe ) . ( Development Title Section 9 - 1710 . 2 [ g ] ) <br /> j . TREE PRESERVATION : Future development on the parcel ( s ) shall be consistent with the <br /> requirements of the County' s Tree Preservation Ordinance ( Development Title Section 9 - 1505 . 2 ) . <br /> k . BUILDING CODE REQUIREMENTS : The following California Building Code ( CBC ) and San Joaquin <br /> County Ordinance requirements will be applicable to the proposed project . The following conditions <br /> shall be addressed prior to submittal of a building permit application to the Building Inspection Division : <br /> ( 1 ) A building permit for each separate structure or building is required . Submit plans , specifications <br /> and supporting calculations , prepared by a Registered Design Professional ( architect or engineer) <br /> for each structure or building , showing compliance with the 2013 California Building , Mechanical , <br /> Plumbing , Electrical , Energy and Fire Codes as may be applicable . Plans for the different buildings <br /> or structures may be combined into a single set of construction documents . <br /> ( 2 ) A soils report in compliance with Chapter 18 of the California Building Code is required . <br /> ( 3 ) Accessibility per Chapter 11 B of the California Building Code is required . In particular , note that <br /> the accessible parking space shown on the development site plan must be located as close as <br /> practicable to the Control Room . <br /> 2 . DEPARTMENT OF PUBLIC WORKS ( Contact ( 209 ) 468 - 3000 , see memo dated July 30 , 2018 ) <br /> PA- 1800161 ( SA , TE ) — Conditions of Approval 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.