My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0003330
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
S
>
SQUIRES
>
145
>
2600 - Land Use Program
>
SA-89-45
>
SU0003330
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:29:45 AM
Creation date
9/9/2019 10:19:18 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0003330
PE
2633
FACILITY_NAME
SA-89-45
STREET_NUMBER
145
STREET_NAME
SQUIRES
ENTERED_DATE
11/7/2001 12:00:00 AM
SITE_LOCATION
145 SQUIRES
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\S\SQUIRES\145\SA-89-45\SU0003330\PRIOR TO 2000.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
123
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
7TtLE 22, CALIFORNIA ADMINISTRATIVE CODE TITLE 22, CALIFORNIA ADMINISTRATIVE CODE 1P <br /> Department Approval of Source and Storage Capacities. Article 3. Distribution Reservoirs <br /> OTT Authority cited: Sections 208, 4010.1 (h), Health and Safety Code. Reference: 69600. Basic Design of Distribution Reservoirs. <br /> Sections 4010.1(h),4012,4013 and 4019,Health and Safety Code. <br /> }llSTO (a) Distribution reservoirs shall be covered. <br /> 1. Repealer filed 30.9A5; effective thirtieth day thereafter (Register aS', No.42). (b) Vents, overflows, drain outlets and other reservoir openings shall be <br /> located and constructed to protect the water stored in the reservoir from <br /> 64566 System Pressure. contamination. Vents and overflows shall be screened. Vents shall not open <br /> (a) Changes in distribution systems shall be designed to maintain an upward. Overflows shall be large enough to dispose of reservoir overflow rates <br /> operating pressure at all service connections of not less than 20 pounds per equal to the maximum reservoir filling rate. <br /> square inch gauge (prig) (140 kiloPascals gauge (kPag)) under the following (c) Provisions shall be made to facilitate removal of floating material from <br /> demand conditions: the free water surface and for dewatering the reservoir. <br /> (1) User maximum hour demand. (d) Outlets shall be designed and constructed to minimize movement of <br /> (2) User average day demand plus design fire flow. sediment from the reservoir floor to the distribution system water mains. <br /> (b) In a public water system supplying users at widely varying elevations, (e) Provisions shall be made for isolating reservoirs and appurtenant <br /> a water supplier may furnish a service to a user which does not comply with facilities from the distribution system without causing violation ofto <br /> (a) if the user is fully advised of the conditions under which minimum service 64566 Sl <br /> may be expected and the user's agreement is secured in writing.This waiver (f) Unless the Department's approval is obtained, distribution reservoir <br /> shall be applicable only to individual service connections. sites shall not be used for nonwater works purposes that would: <br /> (c) Water mains shall be designed to have at least five psig (35 kPag) (1) Result in unrestricted public access. <br /> pressure throughout any buried length of the main except when the main is (2) Create a contamination hazard. <br /> removed from service for repairs or maintenance.This requirement shall not (g) Reservoirs shall be disinfected and sampled for bacteriological quality <br /> apply to short lengths of water train near reservoir inlets and outlets provided: in accordance with the procedures described in "Methods for Disinfecting <br /> (1) The water main is on premises owned,leased or controlled by the water Tanks and Reservoirs", American Water Works Association <br /> Journal, 71 <br /> supplier;or <br /> (1):9950 Qanuary 1979). <br /> (2) The prior review and written approval of the Department is obtained. NOTE: Authority cited:Sections 208 and 4010.1(h),Health and Safety Code.Reference. <br /> NOTE Authority cited:Sections 208 and 4010.1(h),Health and Safety Code.Reference: Sections 4010.1(h),4012,4013 and 4019, Health and Safety Code. <br /> Sections 4010.1(h),4012,4013 and 4019,Health and Safety Code. <br /> 64602. Subsurface Distribution Reservoirs. <br /> 64568. Conditions for Adding Service Connections. (a) Subsurface distribution reservoirs shall be lined and shall be located: <br /> A new service connection may be added to a distribution system only if the (1) Above maximum anticipated ground water level. <br /> water system will comply with Section 69562 after the new service connection (2) At least 50 feet (15 meters) from the nearest sewer and at least 150 feet <br /> is added and adding the new service connection will not cause pressure at an (45 meters) from all other sewerage facilities. <br /> existing service connection to be reduced below the standards set in Section (b) The land adjacent to a subsurface distribution reservoir shall be✓h -,d <br /> 64566' to route surface water away from the reservoir. <br /> NOTE Authority cited:Sections 208 and 4010.1(h),Health and Safety Code.Reference: NOTE: Authority cited:Sections 208 and 4010.1 (h),Health and Safety Code.Reference: <br /> Sections 4010.1(h),4012,4013 and 4019,Health and Safety Code. Sections 4010.1 (h),4012,4013 and 4019,Health and Safety Code. <br /> 64570. Internal Combustion Engines. HISTORY: <br /> (a) Where water cooling jackets for internal combustion engines are 1. Repealer of subsection (c) filed 10-9.85;effective thirtieth day thereafter (Register <br /> connected to water mains, the jacket shall be designed so that the water s5,No.42). <br /> pressure inside the water main at the cooling jacket will at all times be greater 64604. Corrosion Protection. <br /> than the engine coolant pressure. Paints or other protective coatings shall comply with AWWA Standard <br /> (b) Bacldlow protection of the public water system shall be provided D102-78. <br /> wherever makeup water is supplied to the cooling system of an internal NOTE. Authority cited:Sections 208 and 4010.1(h),Health and Safety Code.Reference: <br /> combustion engine. Sections 4010.1(h),4012,4013 and 4019,Health and Safety Code. <br /> NOTE: Authority cited:Sections 208 and 4010.1(h),Health and Safety Code.Reference: <br /> Sections 4010.1(h),4012,4013 and 4019,Health and Safety Code. <br /> HISTORY: <br /> 1. Amendment fled 109-85;effective thirtieth day thereafter (Register 85, No.42). <br />
The URL can be used to link to this page
Your browser does not support the video tag.