Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
12 (STATE ROUTE 12)
>
7101
>
2600 - Land Use Program
>
PA-1600024
>
SU0010779_SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 3:46:26 PM
Creation date
9/9/2019 10:27:07 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SU0010779
PE
2622
FACILITY_NAME
PA-1600024
STREET_NUMBER
7101
Direction
E
STREET_NAME
STATE ROUTE 12
City
LODI
Zip
95240-
APN
04913052
ENTERED_DATE
2/5/2016 12:00:00 AM
SITE_LOCATION
7101 E HWY 12
RECEIVED_DATE
2/5/2016 12:00:00 AM
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\T\HWY 12\7101\PA-1600024\SU0010779\SS STUDY.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
61
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
6.7 Discussion of any potential problems predicted and/or the need for an engineered or <br /> ' alternative septic system. In this area,the soils are classified as San Joaquin Sandy Loam. Due <br /> to this classification and percolation rate, a standard septic system would be recommended on <br /> subject parcel. <br /> ' 6.8 Discussion of percolation rates in relation to the type, size and location of future leach <br /> fields needed at the site. Based on the results of the percolation rate and the soils profile, it is <br /> ' Dillon&Njurphy's opinion that the subject proposed parcels are suited fee a typic on--site sewage <br /> disposal system. The systems should be properly designed and installed-according to-the current <br /> San Joaquin-County criteria for standard septic systems. <br /> Based on the depth to groundwater in the area,and the size of the proposed parcels,it is our opinion <br /> on that the installation of any new proposed septic system, if property installed, should not <br /> adversely affect the quality of groundwater in the area. <br /> 7,0 CONCLUSION SECTION <br /> The conclusions of this report are based on the information provided regarding the proposed <br /> development, the use of the subject property, and the site conditions as they existed at the time we <br /> ' excavated our test holes and performed the percolation tests. It was assumed that the test holes <br /> and percolation test results are representative of the subsurface conditions in the general area. <br /> ' Our services were performed, our findings obtained, and our conclusions proposed in accordance <br /> with generally accepted engineering principles and practices. The warranty is in lieu of all other <br /> warranties either expressed or implied. Test findings and statements of professional opinion do <br /> not constitute a guarantee or warranty, expressed or implied. <br /> 1 1 <br /> �-� Joe urphy <br /> No.y.;=r i' C. 45277 <br /> & 9 3;1-1 d <br /> 1 <br /> 1 <br /> 1 <br /> ' 4 <br />