Laserfiche WebLink
ENVIRONMENTAL HEALTHDEPARTMENT <br /> SAN JOAQUIN COUNTY <br /> �.•"r��•:L Unit Supervisors <br /> Donna K.Horan,R.E.H.S. <br /> 304 East Weber Avenue, Third Floor Carl Borgman,R.Ex.s, <br /> 0. Director Mike Huggins,R.E.H.S.,R.D.I. <br /> `y- Al Olsen,R.E.H.S. Stockton, California 95202-2708 <br /> Douglas W.Wilson,R.E.H.S. <br /> �Q. a�4• Program Manager Telephone: (209) 468-3420 Margaret Lagorio,R.E.H.S. <br /> L!Fola Laurie A.Cotulla,R.E.H.S. Robert McClellon,R.E.H.S. <br /> Program Manager Fax: (209) 464-0138 Mark Barcellos,R.E.H.S, <br /> May 6, 2002 <br /> TO: San Joaquin County <br /> Community Development Department <br /> FROM: Public Health Services <br /> Environmental Health Division <br /> CONTACT PERSON: Johnny Yoakum, Sr. R.E.H.S. <br /> PHONE NUMBER: (209)468-3147 <br /> RF,; PA-02-146 (SA),Attention: Leanne Mueller <br /> 9301 West State Route 12,Lodi <br /> The San Joaquin County Development Title Requirements listed below have been identified as <br /> pertinent to this project. Other requirements may also apply. These requirements cannot be <br /> modified. <br /> A. Environmental Health Division requires a soil suitability/nitrate loading study incorporating <br /> the number of proposed employees and customer use, indicating that the area is suitable for <br /> septic tank usage and winery waste. This must be performed prior to issuance of building <br /> permits and/or final occupancy approval (San Joaquin County Development Title, Section 9- <br /> 1105.2(d)). A nitrate loading study is required and a review fee of$445.00 must be paid at <br /> time of submittal to Environmental Health Division. <br /> The sewage disposal system shall comply with the on site sewage standards of San Joaquin <br /> County prior to approval. A percolation test that meets absorption rates of the manual of <br /> septic tank practice or E.P.A. Design Manual for onsite wastewater treatment and disposal <br /> system is required for each parcel. A permit fee of$89.00 per percolation hole is required. <br /> B. The existing private water wells shall be tested for the chemical dibromochloropropane <br /> (DBCP) and nitrates prior to issuance of building permit(s) and/or final occupancy approval. <br /> tjo3 Samples are to be taken and analyzed by a State-approved laboratory. (San Joaquin County <br /> Development Title, Section 9-1115.7). <br /> C. State on revised site plans the maximum number of employees and customers the sewage <br /> disposal system is being designed for. Show on revised plans that the leach field area will be <br /> barricaded so it cannot be driven over, parked on, or used as a storage area. This leach field <br /> area must be used for that specific purpose only, and it cannot contain any underground <br /> utility lines. In addition,provide the required 100%replacement area for the existing and <br /> proposed sewage disposal area(s) (San Joaquin County Development Title, Section 9- <br /> 1110.4(c)(5)). <br /> Page 1 of 2 <br /> 5 - -° ..'" <br />