Laserfiche WebLink
e. ACCESS AND CIRCULATION: The following requirements apply and shall be shown on the Site <br /> Plan: <br /> (1) Access driveways shall have a width of no less than twenty-five (25) feet for two-way aisles and <br /> sixteen (16) feet for one-way aisles, except that in no case shall driveways designated as fire <br /> department access be less than twenty (20)feet wide. (Development Title Section 9-1015.5[h][1]) <br /> f. LIGHTING: Lighting shall be provided and comply with the following: <br /> (1) If the parking area is to be used at night, parking lot and security lighting shall be installed. <br /> (Development Title Section 9-1015.5[g]) <br /> (2) Any lighting shall be designed to confine direct rays to the premises. No spillover beyond the <br /> property lines shall be permitted except onto public thoroughfares, provided, however, that such <br /> light shall not cause a hazard to motorists. (Development Title Section 9-1015.5[g][4]) <br /> g. LANDSCAPING: Landscaping shall be provided and comply with the following: <br /> (1) A minimum ten (10) foot wide landscaped strip, respecting the ultimate right-of-way width of State <br /> Route 33 and Durham Ferry Road, shall be installed across the frontage of the project site. <br /> (Development Title Section 9-1020. 7[a]) <br /> h. SCREENING: Screening shall be provided and comply with the following: <br /> (1) A solid masonry wall six (6) to seven (7) feet in height shall be erected along the eastern property <br /> line of APN 255-310-23. (Development Title Section 1022.4[d][11) <br /> (2) All storage materials and related activities, including storage areas for trash, shall be screened so <br /> as not to be visible from adjacent properties and public rights-of-way. Screening shall be six (6) <br /> to seven (7) feet in height. Outside storage is not permitted in front yards, street side yards, or in <br /> front of main buildings. (Development Title Section 1022.4[d][2]) <br /> i. NOISE: If noise sensitive development is proposed within 97 feet from the edge of State Route 33 <br /> along the western portion of APN 255-310-23, then a noise study shall be required prior to noise <br /> sensitive development and construction must comply with recommended mitigation measures to <br /> achieve compliance with the standards specified in Table 9-1025.9. (General Plan Table IIID-5B, <br /> Volume III, page III.D-38) (Development Title Section 9-1025.9(a)[1]) (Development Title Section 9- <br /> 1025.9(d)[4]) <br /> j. SIGNS: Sign details shall be consistent with Chapter 9-1710 of the Development Title and be <br /> included on the Site Plan. All portions of any sign shall be set back a minimum of five (5) feet from <br /> any future right-of-way line, including any corner cut-off (snipe). (Development Title Section 9- <br /> 1710.2[g]) <br /> k. BUILDING CODE REQUIREMENTS: The following California Building Code (CBC) and San Joaquin <br /> County Ordinance requirements will be applicable to the proposed project. The following conditions <br /> shall be addressed prior to submittal of a building permit application to the Building Inspection <br /> Division: <br /> (1) A building permit application including plans will be required. According to state law, the plans <br /> must be prepared by a registered engineer or licensed architect and shall be submitted for review <br /> and approval. <br /> (2) The required plans must be complete at the time of submittal for a building permit. Plans must <br /> address building design and construction, fire and life safety requirements, accessibility and show <br /> compliance with the current California codes and San Joaquin County ordinances. A complete <br /> set of plans must include fire sprinkler plans, truss calculations, energy calculations, plumbing, <br /> electrical and mechanical drawings as well as structural calculations. <br /> PA-1400037 (SA) Conditions of Approval 2 <br />