My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0005891 SSNL
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
11265
>
2600 - Land Use Program
>
PA-0600020
>
SU0005891 SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:31:50 AM
Creation date
9/9/2019 10:35:18 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SU0005891
PE
2625
FACILITY_NAME
PA-0600020
STREET_NUMBER
11265
Direction
N
STREET_NAME
THORNTON
STREET_TYPE
RD
City
LODI
Zip
95240
APN
05520003
ENTERED_DATE
1/24/2006 12:00:00 AM
SITE_LOCATION
11265 N THORNTON RD
RECEIVED_DATE
1/24/2006 12:00:00 AM
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\T\THORNTON\11265\PA-0600020\SU0005891\NL STDY.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
70
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
5 = Sufficient I 1 <br /> I = Insufficient <br /> S I 6.0 PERCOLATION TEST INFORMATION SECTION <br /> ® `8' 6.1 Site map showing the location,with concise and accurate dimensions of the percolation test holes on the parcel. <br /> ® -0} 6.2 The minimum number of shallow and deep percolation tests was performed for each parcel. <br /> ® 1�1- 6.3 Description of the date,time and protocol used to prepare the test hole, including depth and dimensions of hole, <br /> preparation of hole, and depth of water used to presoak(minimum 12 inches). <br /> ® 6.4 Description of the date,time and condition of the test hole after the 24-hour soak period (hole still intact, hole dry, <br /> depth to water remaining in hole, etc.) <br /> ® 6.5 The test conformed to SJC Policy EHD 02-02 (correct depth, diameter,2"gravel,6"water refill, correct readings <br /> recorded). <br /> ® 'El- 6.6 Complete Percolation Test Form (including readings)was provided with RENS verification signature. The rate <br /> I was correctly calculated using the last reading. <br /> i <br /> ® 6.7 Discussion of any potential problems predicted and/or the need for an engineered or alternative septic system. <br /> 6.8 Discussion of percolation rates in relation to the type, size and location of future leach fields needed at the site. <br /> 7.0 CONCLUSION SECTION <br /> ® 7.1 The report was signed and stamped by the appropriately registered individual <br /> Reviewed By: Michael F. Escotto Reviewed Date: 10/25/2006 <br /> EHD 26-02-003 Pa 2 of 3 <br /> Page Soil Suitability Checklist <br />
The URL can be used to link to this page
Your browser does not support the video tag.