Laserfiche WebLink
Waddell Property Page 7 of 8 <br /> NOA Job Number: E07156A <br /> November 1, 2007 <br /> 6.7 Discussion of Percolation Test Results <br /> The soils within the sewage disposal areas on each proposed parcel of the site have <br /> demonstrated a satisfactory percolation rate in accordance with the requirements of the EHD <br /> for the use of a standard septic system. <br /> 6.8 Discussion of Septic System Sizing <br /> Septic System Construction should follow the San Joaquin County On-Site Wastewater Disposal <br /> Standards where applicable. <br /> Septic system construction utilizing leach lines and pits should follow the San Joaquin County v� <br /> On-Site Wastewater Disposal Standards where applicable. According to county groundwater <br /> maps, ground water in the vicinity of the site is between 110 and 120 feet below ground <br /> surface. No ground water was found during the drilling of our 25 foot deep holes on October 8, <br /> 2009. <br /> 7.0 CONCLUSIONS <br /> In summary, percolation rates that meet the minimum EHD standards were achieved in the <br /> proposed septic disposal areas of each of the proposed parcels. The parcels appear suitable for <br /> the use of a standard septic system utilizing seepage pits to 25 feet in depth. <br /> No ground water was encountered during the drilling of two (2), 25 foot deep holes on the <br /> property. water sample was taken from thp.on site well per the request of*"i- ^l"�.:^rre <br /> 8.0 LIMITATIONS <br /> The conclusions of this report are based on the information provided regarding the existing and <br /> proposed development, the use of the subject property, and the site conditions as they existed <br /> at the time we excavated our test holes and performed the percolation tests. It was assumed <br /> that the test holes and percolation test results are representative of the subsurface conditions in <br /> the general area. <br /> Our professional services were performed, our findings obtained, and our conclusions proposed <br /> in accordance with generally accepted engineering principles and practices. This warranty is in <br /> lieu of all other warranties either expressed or implied. Test findings and statements of <br /> professional opinion do not constitute a guarantee or warranty, expressed or implied. <br /> 902 Industrial Way•Lodi,CA 95240•209.367.3701 •Fax 209.369.4228 ©2007 Nei!O.Anderson&Associates.Inc <br />