Laserfiche WebLink
Oct-08-03 02 : 51P P . 05 <br /> r„ <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> SAN JOAQUIN COUNTY <br /> Donna K.Rerun.R.L.H.S. UnirSapervisors <br /> ' Director. 304 East Weber Avenue,Third Floor Carl Horgituin,R.E.I-I.S. <br /> At Olicn,R.E.H.S. Stockton, California 95202-2708 Mikc Httggius,11.17.11 S..R.O.I. <br /> P r Manager Telephone: (209) 468-3420 Douglas W.W <br /> ilson,R.E.H.S <br /> . <br /> tsurie A.Cotulla, .r.Hti. Margaret Lagoru,RIMS. <br /> Program Manager Fax: (209) 464-0138 Robert McClellan.R.E.H.S. <br /> Mark Anrccllos.R.E.tI.S. <br /> October 8,2003 <br /> TO: San Joaquin County <br /> Community Development Department <br /> FROM: San Joaquin County <br /> Environmental I lealth Department <br /> CONTACT PF,RSON: Justin Hess, E.H.S. I jn <br /> PHONE NUMBER: (20.9)468-3453 <br /> RE: PA-03-484 (SA),Attention: Jose Rubianes <br /> 28644 South Tracy Boulevard,Tracy <br /> The San Joaquin County Development Titic Requirements listed below have been identified as <br /> pertinent to this project. Other requirements may also apply. These requirements cannot be <br /> modified. <br /> A. Environmental Ilealth Department requires a soil suitability/nitrate loading study <br /> incorporating proposed staff and customer use,indicating that the arca is suitable for septic <br /> tank usage. This must be performed prior to issuance of building permits(San Joaquin <br /> County Development Title,Section 9-1105.2(4)). A nitrate loading study is required,and a <br /> review fee of$465.00 must be paid at time of'submittal to Environmental Health <br /> Department. <br /> The sewage disposal system shall comply with the on site sewage standards of San Joaquin <br /> County prior to approval. A percolation test that meets absorption rates of the manual of <br /> septic tank practice i>r E.P.A. Design Manual for onsite wastewater treatment and disposal <br /> system is required for each parcel. A permit fee of$93.00 per percolation hole is required. <br /> B. State on revised site plans the maximum number proposed employees and customers the <br /> sewage disposal system is being designed for and that the leach held area will be barricaded <br /> so it cannot be driven over,parked on,or used as a storage area. This leach field area must <br /> be used for that specific purpose only,and it cannot contain any underground utility lines <br /> (San Joaquin County Development Title, Section 9-1110.4(c)(5)). <br /> In addition,the applicant shall demonstrate a 100% designed septic system replacement arca in <br /> accordance to the San Joaquin County Sewage Standards. <br /> NOTE: It appears that it concrete slab and proposed parking lot are covering over the existing <br /> leach field in violation of"San Joaquin County Sewage Standards(Permit# 77-565, <br /> dated July 12, 1977). <br />