KLEINFELDER <br /> i <br /> f <br /> 3 <br /> The above is a general summary of the soil and groundwater conditions encountered in the <br /> borings drilled at the site. More-detailed descriptions of the soils encountered in the borings are <br /> noted on the Logs of Borings, Appendix A, Plates A-4 through A-8. All soils have been classified <br /> according to the Unified Soil Classification System (USCS) and Log Key which are described on <br /> i Plate A-2 and A-3, respectively, of Appendix A. <br /> 3. Laboratory Testing <br /> Two unconfined compression tests were performed on large block samples (Photograph 1, <br /> Appendix A) obtained at depths between 40 and 50 feet below grade at the adjacent Grarlite Tracy <br /> Pit excavation on February 27, 1998. Samples were trimmed as best as possible and capped with <br /> hydrocal gypsum. The results of the Unconfined Compressive tests are 2,880 pounds per square <br /> foot (pso and 7,200 psf. Previously performed strength tests from remodeled, reclaimed soils <br /> I from the nearby Teichert Pit were used for strength values below. <br /> Lab tests were performed on selected samples obtained from the borings in order to evaluate the <br /> strength characteristics of the soils encountered. The tests performed consisted of Unconfined <br /> Compression, Direct Shear tests and Moisture Density Determinations. The results of these tests <br /> are noted at the corresponding sample locations, and the Direct Shear test results are presented on <br /> Plates A-10 and A-11 of Appendix A. <br /> I <br /> i 4. Slope Stability Analysis <br /> i <br /> The existing slopes at the Granite Tracy Pit confirm that the sand and gravel deposits are partially <br /> cemented_ Reference is made to photograph 2 on Plate A-12 which shows an approximate 75- <br /> foot high, near-vertical (112 :1) slope at the existing Granite Tracy Pit. This slope was <br /> approximately 120 feet high in the past, prior to placing reclaimed soils at the base of the slope. <br /> This slope has been in place for at least several years and has performed well, even during the past <br /> very-wet winters. Very. little erosion was observed, and teeth marks from excavation operations <br /> j were still present. These materials have more inherent cohesion than would normally be assumed, <br /> 1 considering grain size distribution only. The laboratory tests on block samples from this area <br /> justify relatively high shear strength parameters. <br /> } i <br /> i We have also back calculated strength parameters on the 120-foot high, %z:1 slope described <br /> above based on a static Factor of Safety of 1.1. These strength values are still less than the <br /> results obtained from our block samples. Using these strength values in our analysis increases <br /> the Factors of Safety reported in Table 2 by about 0.2. <br /> i <br /> i ) As in previous studies for other sand and gravel operations, we have relied on the performance of <br /> existing slopes or test excavations and on strength tests performed on relatively undisturbed <br /> samples to evaluate input values for our computer analyses. Lab strength tests have not been <br /> 20-1108-18/M i 88096 Page 3 of 7 <br /> Z) 1998 KleinPelrler Inc <br />