Percolation Test <br /> One shallow percolation test was conducted on the Site; the shallow soil boring 6� <br /> discussed above was used for the percolation test hole (Plate 2). Percolation test <br /> procedures conformed to San Joaquin County Environmental Health Department policy. <br /> Preparation and Presaturation of Percolation Test Holes <br /> After the boring was advanced by hand auger and the soils logged, the test hole was <br /> completed for the percolation test. Approximately one inch of pea gravel was placed in <br /> the bottom of the open soil boring, followed by a 1.5-inch diameter PVC pipe with <br /> perforations on the bottom. Pea gravel was then used to backfill a few inches of the <br /> annular space. <br /> Live Oak presaturated the percolation test hole approximately 24 hours prior to the <br /> percolation test. The hole was filled with water to a height of 12 inches above the <br /> bottom of the boring for the presaturation. On the day of testing, the percolation test <br /> hole was found to be intact and dry. � <br /> Percolation Test Procedure <br /> Live Oak conducted the percolation test for the boring on .lune 3, 2010. Due to soil <br /> conditions, a four-hour test was preferred. Water level measurements were taken every <br /> half-hour during this four-hour period. Michael Escotto, Senior Registered <br /> Environmental Health Specialist at the San Joaquin County Environmental Health <br /> Department, observed the last half-hour of the test. 0� 0 <br /> An electronic well sounder with a depth accuracy of 11100th foot was utilized for the <br /> water level measurements. The water level was measured against a fixed reference <br /> point on the well casing. Measurements were recorded on the data sheet in decimal <br /> feet. When necessary after measuring the water level, the hole was refilled with water <br /> to an approximate level of six inches above the bottom of the hole. <br /> Percolation Test Results <br /> The completed percolation test form is included in Appendix 3 of this report. The form <br /> was signed by Mr. Escotto and indicates a percolation rate for the hole based on the l <br /> final water drop observed. <br /> Per San Joaquin County Environmental Health Department's definition, a shallow <br /> percolation test hole has a depth between 36 and 42 inches; a satisfactory percolation <br /> rate for a shallow test is less than or equal to 60 minutes per inch (min/in) drop. A deep <br /> percolation test hole has a depth greater than 3.5 up to 25 feet; a satisfactory <br /> percolation rate for a deep test is 30 min/in or less. For the Site to utilize a standard <br /> LOGE1013 Page 6 <br />