My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0001214
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
V
>
VICTOR
>
13100
>
2600 - Land Use Program
>
LA-01-15
>
SU0001214
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:28:31 AM
Creation date
9/9/2019 10:58:37 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0001214
PE
2690
FACILITY_NAME
LA-01-15
STREET_NUMBER
13100
Direction
E
STREET_NAME
VICTOR
STREET_TYPE
RD
City
LOCKEFORD
ENTERED_DATE
10/17/2001 12:00:00 AM
SITE_LOCATION
13100 E VICTOR RD
RECEIVED_DATE
3/12/2001 12:00:00 AM
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\V\VICTOR\13100\LA-01-15\SU0001214\APPL.PDF \MIGRATIONS\V\VICTOR\13100\LA-01-15\SU0001214\CDD OK.PDF \MIGRATIONS\V\VICTOR\13100\LA-01-15\SU0001214\EH COND.PDF \MIGRATIONS\V\VICTOR\13100\LA-01-15\SU0001214\EH PERM.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SITE PLAN CHECK LIST d <br /> z - - <br /> • Size. The site plan must be drawn on 16"x 2B"reproducible material. <br /> North Arrow,Date and Scale: Use an engineer's scale(l.e.,1"to 20'or 1"to 40,preferred). The direction of"north" <br /> • should be pointing towards the top of the page. <br /> Streets and Easements: Location and names of all streets and easements bordering on the property with access <br /> details. <br /> Property Unes: All existing and proposed property lines or boundary lines of the parcel with dimensions. Label <br /> each Parcel 1,2,3,4,etc.and indicate the not square footage(acreage)of each. <br /> • Vicinity Map: A vicinity map showing the location of the property in relation to surrounding streets. <br /> • Names and Slgnatures: Name,signature,address and telephone number of owner;the name,address and <br /> telephone number of the owner,surveyor or engineer filing the map. <br /> • Contour Lines. Contour lines or spot elevation relative to mean sea level datum. <br /> • Dedications: improvements and easements to be dedicated to the County. <br /> • Existing and Proposed Development: All existing structures(labeled'existing)and any proposed structures <br /> (labeled proposed)with dimensions,square footage and distances from other structures and existing and <br /> proposed property lines. Any existing structures planned for removal should be shown with dashed lines. The use <br /> and number of floors should be labeled on each structure. <br /> i <br /> • Parking and Driveways: The location,dimensions and surface material of all existing and proposed parking and <br /> driveways. <br /> • Water Wells. The location of existing and proposed water wells on slte and any off-site wells within 150'of the <br /> proposed development Welts must be meet the following setbacks: <br /> 5'from structures; <br /> 50'from septic tanks; <br /> 100'from leach lines; <br /> 150'from sumps or seepage pits,and <br /> 10'from property lines. <br /> If public water will be utilized,a"willserve"letter must be submitted from the service provider. <br /> • Sewers and Septic Tanks: The location of the sewer outlet public sewer hook-up,or existing and proposed sewage <br /> disposal systems Including leach field areas and any off-site sewage disposal systems within 150'of the property. <br /> Septic tanks must meet the following setbacks: <br /> b'from property lines,structures,m driveways and swimming pools; <br /> 50'from water wells. <br /> Leach lines must meet the following setbacks. <br /> 10'from structures,driveways and swimming pools; <br /> 100'from wells,streams and waterways. <br /> 510 75'from property lines depending on zoning or the location of septic systems on adjoining properties <br /> (this requirement also applies to seepage pits). <br /> if public sewage disposal will be utilized,a-will-serve"letter must be submitted from the service provider. <br /> • Storm Drainage. The location of existing and proposed storm drainage facilides(check with Engineering staff <br /> regarding design criteria). If subject to flooding,the 100-year flood elevations must be shown. indicate any <br /> unusual topographic features of the she(e.g.steep slopes,or drainage courses). <br /> • Watercourses: The location of existing watercourses and the extent of any levee,with toe and crown Indicated <br /> • Fh)oding. The area subject to flood from an intermediate regional flood and depth of flood waters,if applicable. <br /> Proposed method of flood protection If property Is subject to Inundation from an intermediate regional flood or <br /> other flood hazard. <br /> - <br /> • Before applying,check your site plan to make sure that it contains all of the Information cited above. You are <br /> encouraged to have one of our counter staff review the draft Site Plan prior to having copies run. <br /> • Faint prints and light blue lines cannot be accepted because they cannot be reproduced or mlcroflimed <br /> 10:03 MPA-LA"February 1.19" <br /> -6- <br /> I <br />
The URL can be used to link to this page
Your browser does not support the video tag.