My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0006510
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
4141
>
2600 - Land Use Program
>
PA-0700130
>
SU0006510
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/20/2019 10:09:31 AM
Creation date
9/9/2019 11:04:46 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0006510
PE
2631
FACILITY_NAME
PA-0700130
STREET_NUMBER
4141
Direction
N
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
APN
11531022
ENTERED_DATE
4/10/2007 12:00:00 AM
SITE_LOCATION
4141 N WEST LN
RECEIVED_DATE
4/10/2007 12:00:00 AM
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\sballwahn
Supplemental fields
FilePath
\MIGRATIONS\W\WEST\4141\PA-0700130\SU0006510\CDD OK.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
24). (2 spaces are required for every 1,000 feet of building area) (0.67 space is required for <br /> every employee). (Development Title Section 9-1015.3) <br /> g. ACCESS AND CIRCULATION: The following requirements apply and shall be shown on the Site <br /> Plan: <br /> (1) Access driveways shall have a width of no less than twenty-five (25) feet for two-way aisles and <br /> sixteen (16) feet for one-way aisles, except that in no case shall driveways designated as fire <br /> department access be less than twenty(20)feet wide. <br /> h. LIGHTING: Lighting shall be provided and comply with the following: <br /> (1) Parking lot and security lighting shall be installed. (Development Title Section 9-1015.5[g]) <br /> (2) Any lighting shall be designed to confine direct rays to the premises. No spillover beyond the <br /> property lines shall be permitted except onto public thoroughfares, provided, however, that such <br /> light shall not cause a hazard to motorists. (Development Title Section 9-1015.5[g][4]) <br /> i. LANDSCAPING: Landscaping shall be provided and comply with the following: <br /> (1) A minimum ten (10) foot wide landscaped strip, respecting the ultimate right-of-way width of <br /> West Lane, shall be installed across the frontage of the project site. (Development Title Section <br /> 9-1020.7) <br /> (2) All areas not used for buildings, parking, driveways, walkways, approved outdoor storage areas, <br /> or other permanent facilities shall be landscaped. (Development Title Section 9-1020.7) <br /> (3) Areas of the property which are not part of the project shall be barricaded from traffic and kept <br /> mowed and dust free. <br /> (4) The parking area shall be landscaped as specified in Section 9-1020.5 of the Development Title. <br /> The parking area shall be provided with a minimum of five percent(5%)of landscaping within the <br /> perimeter of the parking area, not including landscaping along the street frontage. <br /> j. SCREENING: Screening shall be provided and comply with the following: <br /> (1) All storage materials and related activities, including storage areas for trash, shall be screened <br /> so as not to be visible from adjacent properties and public rights-of-way. Screening shall be six <br /> (6)to seven (7)feet in height. Outside storage is not permitted in front yards, street side yards, or <br /> in front of main buildings. (Development Title Section 1022.4[d][2]) <br /> k. SIGNS: Sign details shall be consistent with Chapter 9-1710 of the Development Title and be <br /> included on the Site Plan. All portions of any sign shall be set back a minimum of five (5) feet from <br /> any future right-of-way line, including any corner cut-off (snipe). (Development Title Section 9- <br /> 1710.2[g]) <br /> I. BUILDING CODE REQUIREMENTS: The following Uniform Building Code and San Joaquin <br /> County Ordinance requirements will be applicable and shall be incorporated in the construction plans <br /> before submittal to the Building Inspection Division: <br /> (1) The Construction Site Plan shall indicate the following: <br /> A. Provide parking for the physically disabled. The space(s) shall be located as close as <br /> possible to the primary entrance(C.C.R., Title 24). <br /> Conditions of Approval -2 - PA-0700130 <br />
The URL can be used to link to this page
Your browser does not support the video tag.