• A shallow percolation test was conducted on each proposed parcel of the Site. The soil <br /> borings discussed above were used for the percolation test holes (Plate 10). (, <br /> Percolation test procedures conformed to San Joaquin County Environmental Health <br /> Department policy. <br /> Preparation and Presaturation of Percolation Test Holes <br /> After the borings were advanced by hand auger and the soils logged, the test holes <br /> were completed for the percolation tests. Approximately one inch of pea gravel was <br /> placed in the bottom of each open soil boring, followed by a 2.0-inch diameter PVC pipe <br /> with perforations on the bottom. Pea gravel was then used to backfill a few inches of <br /> the annular space. <br /> Live Oak presaturated the percolation test holes approximately 24 hours prior to the <br /> percolation testing. The holes were filled with water to a height of 12 inches above the {J <br /> bottom of the boring for the presaturation. On the day of testing, all four holes were <br /> found to be intact and dry. <br /> Percolation Test Procedure <br /> Live Oak conducted the percolation tests for the borings on April 4, 2017. Due to soil <br /> • conditions observed, four-hour tests were selected. Water level measurements were <br /> taken every 30 minutes during this four-hour period. The last half hour of each test was <br /> observed by Michael Escotto, Senior Registered Environmental Health Specialist at the <br /> San Joaquin County Environmental Health Department. <br /> An electronic well sounder with a depth accuracy of 1/100th foot was utilized for the <br /> water level measurements. The water level was measured against a fixed reference <br /> point on the well casing. Measurements were recorded on the data sheet in decimal <br /> feet. When necessary after measuring the water level, the holes were refilled with water <br /> to a level of six inches or more above the bottom of the hole. <br /> Percolation Test Results <br /> The completed percolation test forms are included in Appendix 3 of this report. The <br /> forms were signed by Mr. Escotto and indicate the percolation rate for each hole based <br /> on the final water drop observed. <br /> Per San Joaquin County Environmental Health Department's definition, a shallow <br /> percolation test hole has a depth between 36 and 42 inches; a satisfactory percolation <br /> rate for a shallow test is less than or equal to 60 minutes per inch (min/in) drop. For the <br /> Site to utilize a standard septic system, one percolation test per parcel must <br /> demonstrate a satisfactory percolation rate. <br /> • Details and results of the percolation tests are summarized in the following table. <br /> LOGE 1702 Page 7 <br />