Laserfiche WebLink
08/28/2005 20:56 2093694568 WOODBRIDGE FIRE DIS PAGE 03 <br /> WOODBRIDGE FIRE DT"TR>IC><' Application PA-0500531 (UP) <br /> 400 E.Augusta St. Date: 08/029/05 <br /> Woodbridge,Ca.95258 Contact: Steve Dalton <br /> (209)369-1945 cc: Steve Butler <br /> FAX(209) 369-4568 <br /> Uniform Fre Code,San Joaquin County and <br /> Woodbridge Fire District <br /> Ordinance Code Requirements <br /> J. The following Uniform Fire Code and San Joaquin County Ordinance Code requirements will <br /> be applicable and shall be incorporated in the construction plans before submittal to the <br /> Community Development Department for a building permit. <br /> (X)A.Fire flow will be provided for proposed buildings by the use of: <br /> ( ) 1. Appendix III-A of the Uniform Fire Code(public water mains)_ <br /> ( )2.NFPA 1231 of the National Fire Code and San Joaquin County Fire Chiefs <br /> Standards(static water supply). <br /> (X)3. Location/Placement as directed by the Woodbridge Fire District. <br /> (X)B.Fire hydrants shall be supplied in accordance with Appendix III-B if the Uniform Fire <br /> Code. <br /> (X) 1. Type and size as directed by the Woodbridge Fire District <br /> (X)2. Location /Placement as directed by the Woodbridge Fire District. <br /> ( )C. Fire protection systems shall be.installed according to Article 10 of the California Fire <br /> Code and the appropriate standards and guides adopted in Chapter 35 of the California <br /> Building Code and the California Electrical Code. <br /> ( )D. All valves controlling the water supply for automatic fire sprinkler systems and water <br /> flow switches shall be monitored in accordance with 904.3.1 of the California Fire <br /> Code. <br /> ( )E. Fire Department access road shall be in accordance with section 9022 of the <br /> California Fire Code and the standard adopted by the San Joaquin County Fire Chief's <br /> Association. <br /> ( ) 1. Inspection of access roads shall be completed by the Woodbridge Fire <br /> District. <br /> (X)F. Fire Department access to property/buildings shall be in accordance with 902A of <br /> the Uniform Fire Code (Key Boxes). <br /> (X) 1.Key Box and Access Systems information as provided by the Woodbridge <br /> Fire District. <br /> (X)2. Location of key box and or access system as per direction of the <br /> Woodbridge Fire District. <br /> (X)G. Fire extinguishers shall be installed in accordance with California Fire Code,Volume <br /> 2, Standard 10-1. <br /> (X)N_ Fire permits may be required prior to occupancy to conduct operations hazardous to <br /> life or property.California Fire Code 105.2.1. <br /> (X)1. Mechanical Refrigeration Systcros shall comply with all applicable codes. <br /> ( )J.Additional remarks per attachment_ <br /> Form FP 997 <br />