My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COZWFC1DH
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
AURORA
>
1102
>
2500 – Emergency Response Program
>
COZWFC1DH
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/16/2026 1:16:40 PM
Creation date
9/17/2019 4:11:54 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2500 – Emergency Response Program
RECORD_ID
COZWFC1DH
PE
2546 - Release/Spill Response (excluding Joint Team)
STREET_NUMBER
1102
Direction
S
STREET_NAME
AURORA
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
15134001
ENTERED_DATE
4/24/2019 12:00:00 AM
CURRENT_STATUS
Closed
SITE_LOCATION
1102 S AURORA ST
RECEIVED_DATE
4/24/2019 12:00:00 AM
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\tchampion
Supplemental fields
Site Address
1102 S AURORA ST STOCKTON 95206
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
64
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov.ong/ehd <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> DEBCO AUTO WRECKING INC 1102 S AURORA ST, STOCKTON December 21, 2018 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 113 HSC 25160.2(b)(3) Failed to keep copies of consolidated manifesting receipts for three years. <br /> Copies of hazardous waste disposal records for used oil, used antifreeze, used oil filters, and used absorbent were <br /> not found on site. Hazardous waste generators shall retain copies of all manifests signed off by the disposal facility <br /> and all receipts used in a consolidated manifesting procedure on site for three years and have them readily available <br /> for review. Immediately locate a copy of all manifests and receipts for the last three years, maintain them on site, <br /> and submit copies to the EHD. <br /> This is a minor violation. <br /> 115 CCR 66266.81(a)(4)(B) Failed to retain copy of manifest or bill of lading for spent lead acid batteries for 3 years. <br /> Bills of lading or manifests for the management of lead acid batteries for the last three years were not found on site. <br /> A copy of each bill of lading must be kept on site for at least three years. Immediately locate a copy of all bills of <br /> lading or manifests for lead acid batteries for the last three years, maintain them on site, and submit copies to the <br /> EHD. <br /> This is a Class II violation. <br /> 301 CCR 66262.34(d)(2) Facility not maintained to minimize the release of a hazardous waste. <br /> Heavy oily staining was observed on the soil in front of the side shop. <br /> A smashed lead acid battery was observed in front of the side shop with the contents leaking out. <br /> Oily water was observed in front of the shop. <br /> Facilities shall be maintained and operated to minimize the possibility of a fire,explosion, or release of hazardous <br /> waste to air, soil, or surface water which could threaten human health or the environment. Immediately clean the <br /> area,and manage according to Title 22 hazardous waste regulations. Submit a statement and supporting <br /> documentation explaining how this waste was managed. <br /> This is a minor violation. <br /> 403 CCR 66262.34(d)(2) Failed to keep hazardous waste containers closed except when adding or removing hazardous <br /> waste. <br /> In the main shop, oil filters were draining into a pan.All hazardous waste containers shall be closed at all times <br /> except when adding or removing waste. Immediately close the container and ensure all hazardous waste <br /> containers are closed when not adding or removing waste. <br /> This is a minor violation. <br /> 601 CCR 66262.34(d)Stored hazardous waste onsite greater than 180 days. <br /> In the main shop, oil filters were draining into a pan. <br /> Facilities who generate less than 1000 kg of hazardous waste per month and do not exceed 6000 kg of waste <br /> stored on site at any time may store waste on site up to 180 days. Since it cannot be determined how long the <br /> hazardous waste has been on site, immediately contact a licensed hazardous waste hauler to dispose of this waste <br /> under manifest. Submit a copy of the manifest to the EHD within 30 days. <br /> This is a Class II violation. <br /> FA0019931 PRO539009 SC001 12/21/2018 <br /> EHD 22-01 Rev.09/22/16 Page 5 of 7 Small Quantity Hazardous Waste Generator GIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.