Laserfiche WebLink
5 Data Quality Assessment <br /> The October 2018 data were assessed in accordance with the WQSAP (Dudek 2O17a). Data assessment procedures <br /> included review of quality control samples and sample custody documentation. <br /> 5.1 Water Levels <br /> The October 2018 water level measurements and field parameter data were assessed qualitatively for <br /> completeness and comparability to previous field data.The October 2018 field data were deemed satisfactory and <br /> usable based on this assessment. <br /> 5.2 Water Quality <br /> Laboratory analyses of groundwater samples collected in October 2018 were subjected to quality assurance/quality <br /> control evaluation. The evaluation included a review of the results of duplicate analyses, matrix spike recovery <br /> analyses, and holding times. The October 2018 analytical data for VOCs were deemed satisfactory and usable <br /> based on the data assessment. The October 2018 analytical data were also considered representative of <br /> groundwater quality at the site based on comparison with analytical data from September 1988 to the present. <br /> As part of quality control for the VOC analysis,4-bromofluorobenzene, dibromofluoromethane,and toluene-d8 were <br /> added as surrogates to each sample. Analytical results were compared to the known concentration of each <br /> surrogate and reported as a percent recovered. Percent recoveries for dibromofluoromethane all fell within the <br /> quality control limits of 76%to 132%. Percent recoveries for 4-bromofluorobenzene all fell within the quality control <br /> limits of 80%to 120°/x. Percent recoveries for toluene-d8 fell within the quality control limits of 80%to 128%.Thus, <br /> the data were deemed satisfactory. <br /> As part of quality control for the 1,4-dioxane analysis, 1,4-dioxane-d8 and nitrobenzene-d5 were added as <br /> surrogates to each sample. Analytical results were compared to the known concentration of each surrogate and <br /> reported as a percent recovered. Percent recoveries for 1,4-dioxane-d8 fell within the quality control limits of 30% <br /> to 120% in all samples analyzed. The associated method blank 1,4-dioxane-d8 surrogates were within quality <br /> control limits,and the percent recoveries of the nitrobenzene-d5 surrogates were within quality control limits for all <br /> samples analyzed. Therefore,the laboratory deemed the results acceptable. <br /> In addition to surrogates, matrix spike (MS), MS duplicate (MSD), and laboratory control samples were analyzed to <br /> assess accuracy. The MS/MSD percent recoveries for the site were within the quality control limits. Therefore,the <br /> data quality is deemed acceptable. <br /> MS/MSDs were analyzed by the laboratory to assess precision.All MS/MSD relative percent differences were within <br /> quality control limits.Therefore,the data quality is deemed acceptable. <br /> One field blank,one equipment blank,and one trip blank was collected duringthe October 2018 groundwater monitoring <br /> event. No VOCs were detected above the MDLs in any of the blanks. <br /> All samples analyzed for VOCs and 1,4-dioxane were analyzed within their holding times. <br /> D U D E K 10886-1 <br /> 19 March 2019 <br />