Laserfiche WebLink
TABLE 1 <br /> Extraction Well and Treatment System Effluent and Injection Monitoring <br /> EC pH Temperature Volume of Water Avg. Water <br /> Monitoring Date field field field extracted&treated Flow Rate Flow Rate Pressure Level <br /> Point µmhos/cm pH units °Celciusgallons GPM GPM psig feet msl <br /> 12/14/2018 104,120 4.8 5 88 -19.19 <br /> 11/29/2018 206,310 4.8 5 86 -19.40 <br /> KI-3 10/30/2018 206,310 4.8 5 88 -20.48 <br /> 6/21/2018 213,520 4.8 5 82 -18.45 <br /> 5/21/2018 219,310 4.7 5 85 -18.15 <br /> 4/19/2018 105,370 4.8 5 88 -18.10 <br /> 12/14/2018 1,486,900 66 68 56 -39.06 <br /> 11/29/2018 2,971,520 68 69 56 -39.49 <br /> KI-5 10/30/2018 4,083,180 70 69 55 -39.25 <br /> 6/21/2018 3,083,100 68 69 56 -37.48 <br /> 5/21/2018 3,169,200 69 69 56 -37.16 <br /> 4/19/2018 1,524,700 69 69 54 -37.20 <br /> 12/14/2018 476,200 23 22 68 -39.63 <br /> 11/29/2018 951,480 22 22 68 -38.87 <br /> KI-12 10/30/2018 1,297,170 22 22 68 -39.64 <br /> 6/21/2018 978,100 22 22 68 -38.51 <br /> 5/21/2018 1,004,540 22 22 66 -38.14 <br /> 4/19/2018 483,240 22 22 68 -37.19 <br /> GPM gallons per minute <br /> msl mean sea level <br /> psig pounds per square inch gauge <br /> The treatment system was shut down from 7/6/18 until 10/4/18 as part of an effort to increase contaminant mass removal efficiency by pulsing the system(in approximately 3-month intervals). <br /> Treatment System O&M Report DUDEK <br /> Former Kearney-KPF Facility, Stockton,CA 2 of 2 2/20/2019 <br />