Laserfiche WebLink
ATTACHMENT 5 <br /> City of Lodi <br /> White Slough Water Pollution Control Facility <br /> Groundwater Monitoring Workplan <br /> Monitoring Well Specifications <br /> January 12, 2001 <br /> Monitoring wells shall be constructed in accordance with the Well Standards issued by <br /> the San Joaquin County Public Health Services - Environmental Health Division and the <br /> California Well Standards issued by the California Department of Water Resources as <br /> Bulletins 74-81 and 74-90. <br /> Monitoring wells shall be constructed with 2-inch nominal diameter, schedule 40, <br /> polyvinyl chloride (PVC) blank and slotted casing. Casing shall be of the flush threaded <br /> type. No solvent welded casing shall be used. The slotted casing shall extend three feet, <br /> minimum, above the highest seasonal water level anticipated. The casing shall be <br /> provided with a plug or seal at the bottom. <br /> Well boreholes shall be constructed with hollow-stem augers of sufficient inside diameter <br /> to permit insertion of the casing through the auger. <br /> Gravel pack material shall be clean and free of organic material. The gravel pack shall <br /> extend a minimum of 1 foot above the top of the slotted casing. <br /> A minimum of 2 feet of bentonite shall be placed above the gravel pack to form a seal <br /> above the saturated zone. The remaining annular space shall be filled with a mixture of <br /> sand and bentonite or neat cement. The sand shall be clean and free of organic material. <br /> The mixture shall contain a minimum of 30 percent granular bentonite. <br /> For aboveground completions, the well casing shall extend 28 inches above the top <br /> surface of the concrete base. The monitoring well shall be protected with a minimum 8- <br /> inch diameter, schedule 40, steel pipe set in concrete. The steel pipe enclosure shall be <br /> primed and painted orange. The concrete shall extend a minimum of 18 inches below the <br /> finished grade. The steel pipe enclosure shall be provided with a hinged cover and hasp <br /> suitable for locking. The bottom of the hinged cover shall be 2 inches above the top of <br /> the well casing. A drain hole shall be provided in the steel pipe to permit draining of the <br /> annular space above the concrete. The well shall be protected with three bollards. The <br /> steel bollards shall be primed and painted orange and filled with concrete. The bollards <br /> shall be set in concrete. The concrete shall extend 18 inches below finished grade. <br /> For subsurface completions, the top of the casing shall be protected with an Emco <br /> Wheaton A722 Monitoring Well Manhole with locking cap and collar. <br /> Page 1 of 1 <br />