Laserfiche WebLink
`r/' v DIVISION OF OIL AND GAS • rkmaw No. P 681-491 <br /> REPORT ON PROPOSED OPERATIONS (Wb code) <br /> (area code) <br /> WELL CLASSIFICATION: -- <br /> DEVELOPMENT (new pool code) <br /> Harrv_ Hull_ -Hull <br /> ARM PETRQ1_-t1_1M C p (old pool code) <br /> p_n_ a"= cI __ Woodland , California <br /> Ventura- Gs 920Q1 October 2- 1981 <br /> Yourproposal to drill well "Buttes-Rio Blanco" 15-77X <br /> AP.1. No.----M--2Q361 Proj- Section_ T.AN R. 5E H•QB. & <br /> --- field, - area, --- pool, <br /> San Joaquin County, dated_ 9-24-81 ,received 9-29-81 has been examined in conjunction with records <br /> filed in this office. <br /> THE PROPOSAL IS APPROVED PROVIDED THAT: <br /> 1. The 8 5/81, casing is cemented with sufficient cement to fill behind this casing from <br /> the shoe to the ground surface. <br /> 2. The 4 1/2" casing is cemented with sufficient cement to fill behind this casing from <br /> the shoe to at least 500 feet above the uppermost oil or gas zone. <br /> 3. Drilling fluid of a quality and in sufficient quantity to control all subsurface <br /> conditions in order to prevent blowouts is used. <br /> 4. Blowout prevention equipment conforming to Class III B 2M requirements is installed <br /> on the 8 5/8" casing and maintained in operating condition at all times. See Manual <br /> P07 and attached sheet. <br /> 5. Blowout prevention equipment conforming to Class "III" 3M requirements is installed <br /> on the 4 1/2" casing and maintained in operating condition atall times. See Manual <br /> M07 and attached sheet. <br /> 6. 1"atcr with any beneficial use is protected from contamination at all times. <br /> 7. The division is furnished copies of any draw down or back pressure tests performed. <br /> In addition the division will monitor the production for a period of six months and <br /> if anomalous water production is indicated, remedial action will be ordered. <br /> 8. THIS DIVISION IS NCTIFIED: <br /> a. Before deviating from the proposed casing program and/or placing any plugs in <br /> the hole. Additional requirements shall be outlined at that time. <br /> b. To witness a test of the installed blowout prevention equipment prior to drilling <br /> out the shoe of the 8 5/8" casing. The blind/blank rams shall be tested by the <br /> operator prior to calling the Division inspector. Test information of the blind/ <br /> blank Yam test shall be entered on the tour sheet along with the signature of the <br /> person in charge. <br /> NOTE: 1. This well has been granted confidential status for two years from the date of <br /> its completion or aband,,nment. <br /> 2. Infor-maticn on fire in this office indicates that the base of the useable <br /> fresh water deposits slould be encountered at a depth of approximately 3001. <br /> Blanket Bcnd <br /> l(PH A w <br /> CC . Co. , Ventura <br /> CONI STAT S <br /> M G. MEFFERD, State Oil and Gas Supervisor <br /> By <br /> John C.Suls�l ivan <br /> A copy of this report and the proposal must be posted at the well site prior to commencing operations. <br /> Records for work done under this permit are due within 60 days after the work has been completed <br /> or the operations have been suspended. <br />