Laserfiche WebLink
v DIVISION OF OIL AND GAS �� No. P 686-204 <br /> REPORT ON PROPOSED OPERATIONS (Held code) <br />' WELL CLASSIFICATION: Development (area code) <br /> (new pool code) <br /> James R. Weddle, Agent <br /> QUINTANA PETROLEUM CORP. (old pool code) <br /> 1406 Easton Drive Suite 33 — Woodland <br /> California <br /> Bakersfield, CA. 93309 June 3, <br /> Your proposal to drill well "Piacentine" 1-27 <br /> A.P.I. No. 077-20484 Section_? T. 3N ,R. 5E M.D. B. & M., <br /> -- field, -- area, -- pool, <br /> San Joaquin County, dated-$/86 ,received_ 30 has been examined in conjunction with records <br /> filed in this office. <br /> THE PROPOSAL IS APPROVED PROVIDED THAT: <br /> 1. The - 8-5/8" casing is cemented with sufficient cement to fill behind this casing frbm <br /> the shoe to the ground surface. <br /> 2. The 51t' casing is cemented with sufficient cement to fill behind this casing from <br /> the shoe to at least 500 feet above the uppermost oil or gas zone. <br /> 3. Drilling fluid of a quality and in sufficient quantity to control all subsurface <br /> conditions in order to prevent blowouts is used. <br /> 4. Blowout prevention equipment conforming to Class III B 2M requirements is installed on <br /> the 8-5/8" casing and maintained in operating condition at all times. See Manual <br /> M07 and attached sheet. <br /> 5. Blowout prevention equipment conforming to Class "III" 2 M requirements is installed <br /> on the casing and maintained in operating condition at all times. See Manual <br /> M07 and attached sheet. <br /> 6. Water with any beneficial use is protected from contamination at all times. <br /> 7. The division is furnished copies of any draw down or back pressure tests performed. <br /> In addition the division will monitor the production for a period of six months and <br /> if anomalous water production is indicated, remedial action will be ordered. <br /> 8. THIS DIVISION IS NOTIFIED: <br /> a. Before deviating from the proposed casing program and/or placing any plugs in the <br /> hole. Additional requirements shall be outlined at that time. <br /> b. To witness a test of the installed blowout prevention equipment prior to drilling <br /> out the shoe of the 8-5/8" casing. The blind/blank rams shall be tested by the <br /> operator prior to calling the Division inspector. Test information of the blind/ <br /> blank ram test shall be entered on the tour sheet along with the signature of the <br /> person in charge. <br /> NOTE: 1. Information on file in this office indicates that the base of the useable <br /> fresh water deposits should be encountered at a depth of approximately 150' <br /> Blanket Bond <br /> RLH/sd <br /> cc: Co. MPprior <br /> , to Oil and Gas Supervisor <br /> Bn C. Sul1livan <br /> A copy of this report and the proposal must be posted at the well sommencing operations. <br /> Records for work done under this permit are due within 60 days after the work has been completed <br /> or the operations have been suspended. <br /> OG111 (11/82/DWRR/5M) <br />