FIELD DOCUMENTS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
AIRPORT
>
5000
>
2900 - Site Mitigation Program
>
PR0540507
>
FIELD DOCUMENTS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/4/2019 3:52:16 PM
Creation date
10/4/2019 3:48:14 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
FIELD DOCUMENTS
RECORD_ID
PR0540507
PE
2960
FACILITY_ID
FA0023167
FACILITY_NAME
STOCKTON METRO AIRPORT FORMER FUEL FARM
STREET_NUMBER
5000
Direction
S
STREET_NAME
AIRPORT
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
17726034
CURRENT_STATUS
01
SITE_LOCATION
5000 S AIRPORT WAY
P_LOCATION
01
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
66
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
------------- -- <br /> MW-4 BUILDING <br /> CRAFT -�. <br /> BUILDING EQUIPMENT <br /> STORAGE <br /> YARD <br /> COVERED <br /> PARKING SIED] w t �� <br /> LANDSCAPE ROCK GATE <br /> MW-5 16 <br /> FORMER <br /> FUEL DISPENSER <br /> �• MW-6 <br /> CPT- <br /> VS-2 SB-4 VEHICLE <br /> "G ^`tip\\� WASH RACK <br /> HANGAR STORAGE.. MW-1 <br /> YARD <br /> CONCRETE 5� VSIf <br /> FORMER <br /> FUEL SPENSER <br /> Citi SB\1`w> LJ <br /> CA 3 <br /> C�y``� O\``ww/A-2<`�� VS-S <br /> .B 3 �W-2 AREER AVIATION USTs (3) <br /> C- <br /> VS"�l•`-`�~-�' <br /> C.E. DIXON STREET <br /> My <br /> Note: 6 additional USTs (Tanks 15-20) were removed from the <br /> Stockton Airport property in 1987 and 1988. They may not be pAPJ <br /> associated with the former fuel farm site. <br /> 0 <br /> o' <br /> LEGEND o <br /> SB-3 <br /> BUILDING U <br /> o SOIL BORING LOCATION (VACANT) O <br /> LIJ <br /> MONITORING WELL LOCATION W <br /> ! I <br /> FORMER UNDERGROUND Y <br /> Li STORAGE TANK U <br /> �— FENCE LINE <br /> CPT LOCATION <br /> 0 80 160 <br /> SOIL VAPOR SAMPLE LOCATION <br /> APPROXIMATE SCALE (FEET) <br /> FZ A M A G E FIGURE 2 <br /> ENVIRONMENTAL <br /> SITE PLAN <br /> P.O.. BOX 18353 <br /> RENO, NEVADA 89511 STOCKTON METROPOLITAN AIRPORT <br /> (775) 851-7239 �Q FORMER AVIATION FUEL STORAGE AREA <br /> Date Prepared Drawing Number 5000 SOUTH AIRPORT NAYSTOCi<TON, CALIFORNIA <br /> 4/14/14_rds ARPRT-F2-0414 <br />