My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS XR0011176
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
2185
>
3500 - Local Oversight Program
>
PR0544922
>
ARCHIVED REPORTS XR0011176
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/7/2019 3:38:56 PM
Creation date
10/7/2019 3:14:34 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0011176
RECORD_ID
PR0544922
PE
3528
FACILITY_ID
FA0003284
FACILITY_NAME
FOOD MART GASOLINE*
STREET_NUMBER
2185
Direction
E
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95205
APN
14113045
CURRENT_STATUS
02
SITE_LOCATION
2185 E FREMONT ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
48
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
REMEDIATION TESTING AND DESIGN March 29 , 1993 <br /> To determine the general vapor flaw chai.acteri,tics in various wells <br /> and at a number of vacuum levels . step testarig was performed in all <br /> vacuum e_.traction wells and in rionit_r well 9W-3 Step test vacuums <br /> ranged from 5 to 22 inches of mercury ( "Hg i with flow rates rai.gin- <br /> from 10 to 55 scfm <br /> ' At the request of Ultramar, the vapor probes were left in the ground <br /> and will be sealed at the surface and plumbed into the treatment <br /> system manifold This modification in the scope of work required a <br /> formal workplan modification/proposal submittal to PHS/EHD for <br /> approval A copy of this submission is contained in Appendix A <br /> RESULTS <br /> Soil Gas Screening <br /> ` Results of the LSCS are presented in Table 1 FID yield screening at <br /> all probe locations , with the exception of P-7 and P-9 , showed no <br /> 1 detectable hydrocarbons The TVH concentration measured in P-7 was <br /> the highest of the probes at 1 , 200 ppmv, and the TVH at P-9 was 140 <br /> ppmv Both of these probes are located in the former UST area. P-7 ' <br /> within the backfilled tangy: pit and, P-9 located below the former pit <br /> Generally, the probes exhibited very poor vapor flow characteristics , <br /> requiring a vacuum of 9 to 10 inches of mercury for a flow rate of 10 <br /> cubic feet per hour ( cfh) Probes P-7 and P-6 (both completed within <br /> the backfilled UST pit) exhibited favorable vapor flow of 20 cfh at a <br /> vacuum of less than 1 inch of mercury Soil gas screening of the <br /> vacuum extraction and monitor wells generally showed high TVH <br /> concentrationLz ( see Table 1 ) The highest TVH readings were recorded <br /> in the "b" zone vacuum extraction wells . <br /> Laboratory analyses of the soil gas samples collected in airbags <br /> showed significant levels of TPHg and BTEX from the wells tasted. <br /> Table 2 is a summary of the laboratory analyses performed for soil <br /> gasses from selected wells The complete laboratory report ( including <br /> chromatograms ) is included in Appendix B The results of the air bag <br /> analyses generally correspond well with the TVH readings except for <br /> monitor well MW-3 . , The "a" zone wells contained elevated levels of <br /> BTEX and TPHg Figure 3 shows the distribution of TPHg in soil gas <br /> from the "a" zone . The highest levels of BTEX and TPHg, were noted in <br /> the "b" zone wells Figure 4 shows the distribution of TPHg in soil <br /> gas from the "b" zone Soil gas samples from VW-2a and VW-2b were <br /> collected for laboratory analysis following the 1-hour flow tests <br /> r conducted in each of those two wells This analysis ( see Table 2) <br /> showed a slight decrease from BTEX and TPHg levels recorded prior to <br /> flow testing <br /> t - <br /> Vacuum Extraction Testing <br /> Table 3 contains VEFT field data for extraction from well VW-2a. The <br /> results of this test show that vacuum ,e:traction works well in the "a" <br /> zone and that extraction from the "a" zone also produce's vapor flow in <br /> the "b" zone , in the zone near the water table and within the <br /> 3 <br />